VB Series Indoor LS Manual 
  High 
Altitude 
Installations 
    
 
 
 
 
 
 
 
 
 
 
 
 
 
0-2000 ft 
(0-610 m) 
2001-5200 ft 
(610-1585 m) 
5201-7700 ft 
(1585-2347 m) 
7701-10200 ft 
(2347-3109 m) 
Switch No. 2 
OFF 
OFF 
ON 
ON 
Switch No. 3 
OFF 
ON 
OFF 
ON 
 
 
 
 
 
 
 
 
 
 
 
 
Set switches 2 and 3 to the values shown in table 
below for your altitude.  The default setting for the 
appliance is 0-2000 ft (0-610 m) with switches No. 2 
and No. 3 in the OFF position. 
  Connecting Multiple Water Heaters   
 
 
 
 
 
 
 
 
 
 
 
 
The EZConnect™ cable is an optional accessory 
that connects 2 water heaters and allows them to 
function as one hot water source.  
The MSA-2M and MSA-2S packs are optional 
accessories that connect 2 to 5 water heaters 
and allow them to function as one hot water 
source. 
Refer to the instructions that come with the 
accessory for complete installation information. 
Number of 
Connected 
Water Heaters: 
Accessories Necessary: 
(1) EZConnect™ Cable 
or
 
(1) MSA-2M 
(1) MSA-2M 
and
 (1) MSA-2S 
(1) MSA-2M 
and 
(2) MSA-2S 
(1) MSA-2M 
and 
(3) MSA-2S 
Guidelines 
•  Do not install both the EZConnect™ and the 
MSA packs because they are not designed to 
operate together. 
•  Water heaters connected with the 
EZConnect™ Cable or the MSA-2M and MSA-
2S packs cannot be used for the bath fill 
function. 
•  Water heaters should be installed less than 18 
inches apart so that the cables will reach 
between units and to prevent temperature 
fluctuations (cold water sandwich effect) when 
the water is shut off and turned back on. 
•  Temperature settings can only be changed on 
the controller for the primary unit.  (This 
changes the temperature on all units within the 
MSA or EZConnect™ system.) 
     WARNING 
DO NOT adjust the other 
switches unless specifically 
instructed to do so. 
Switch No.
F
O
F
8
5
7
6
4
3
ON
1
2
Switch No.
F
O
F
8
5
7
6
4
3
ON
1
2
Switch No.
F
O
F
8
5
7
6
4
3
ON
1
2
Switch No.
F
O
F
8
5
7
6
4
3
ON
1
2
Model 
Number of units 
in standby 
Position of switch No. 5 in 
bank of 6 switches 
RL75, 
RL94  
1 ON 
2 OFF 
(default) 
Activation Options for EZConnect™ 
One unit in standby allows for quicker activation time with 
flow rates within the capacity of a single unit. 
Two units in standby allows for quicker delivery temperature 
for flow rates requiring both units. 
Applicable for the RL75 and RL94 models only.