Rinnai RL75E 用户手册

下载
页码 60
 
 
VB Series Outdoor LS Manual 
Specifications 
Model 
RL75e
 
RL94e
 
R98LSe
 
R98LSe-ASME
 
Minimum Gas Consumption Btu/h  
9,900 (NG) 
10,300 (LPG) 
19,000 
Maximum Gas Consumption Btu/h  
180,000 
199,000 
237,000 
Hot water capacity (Min - Max) * 
0.4 - 7.5 GPM 
(1.5 - 28.5 L/min) 
0.4 - 9.4 GPM 
(1.5 - 35.5 L/min) 
0.6 - 9.8 GPM 
(2.3 - 37 L/min) 
Hot water capacity (45°F rise)  
6.6 GPM 
(25.1 L/min)  
7.1 GPM 
(27.0 L/min)  
8.5 GPM 
(32 L/min) 
Default Temperature Setting (no controller)  
120º F (49º C) 
Temperature Controller Default Setting 
104º F (40º C) 
Maximum Temp Setting (commercial **) 
160º F (71º C)                                                                                                              
185º F (85º C)  
Maximum Temp Setting (residential)  
see Temperature Ranges for more information 
Selectable at 120º F (49º C) or  
at 140º F (60º C) 
 
140º F (60º C) 
 
Minimum Temperature Setting  
98º F (37º C) 
Weight  
51 lb (23 kg) 
 
55 lb (25 kg) 
Efficiency 
Energy Factor:  0.82 
Thermal Efficiency:  83.0%  
 
Noise level  
49 dB (A) 
Electrical 
Consumption  
Normal  
44 W 
49 W 
72 W 
Standby  
2 W  
Anti-frost Protection  
104 W 
116 W 
By-Pass Control  
Fixed 
Electronic 
Minimum Gas 
Supply 
Natural Gas  
5.0 inch W.C. 
Propane  
8.0 inch W.C. 
Maximum Gas 
Supply 
Natural Gas  
10.5 inch W.C. 
Propane  
13.5 inch W.C. 
Type of Appliance  
Temperature controlled continuous flow gas hot water system.  
Operation  
With or without temperature controls, mounted in kitchen, bathroom, etc.  
Approved Gas Type  
Natural Gas or Propane - Ensure unit matches gas type supplied at the installation location. 
Connections  
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT  
Ignition System  
Direct Electronic Ignition  
Electric Connections  
Appliance: AC 120 Volts, 60Hz. Temperature Control: DC 12 Volts (Digital)  
Water Temperature Control  
Simulation Feedforward and Feedback.  
Water Supply Pressure  
Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)  
Maximum Water Supply Pressure  
150 PSI  
Temperature Control Cable  
Non-Polarized Two Core Cable (Minimum 22 AWG) 
Energy Star Qualified 
Yes 
Yes 
No 
No 
Certified for installation in manufactured  
(mobile) homes 
Yes 
Yes 
No 
No 
Energy Factor:  0.82 
Rinnai is continually updating and improving products.  Therefore, specifications are subject to change without prior notice. 
The maximum inlet gas pressure must not exceed the value specified by the manufacturer.  The minimum value listed is for 
the purpose of input adjustment. 
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. 
** for commercial and hydronic applications requiring higher temperatures