Rinnai RC98HPE 用户手册

下载
页码 60
 
 
Manual - Rinnai Condensing Water Heaters 
Suggested temperatures are 
•  Kitchen  120 ºF (49º C) 
•  Shower  98º - 110º F (37º - 43º C) 
•  Bath Fill  102º - 110º F (39º - 43º C) 
These temperatures are suggestions only. 
A temperature lower than 98º F (37º C) can be 
obtained at the tap by mixing with cold water. 
To change the temperature scale from Celsius to 
Fahrenheit or vice versa, press and hold the “On/Off” 
button for 5 seconds while the water heater is OFF. 
  Temperature Options Without a Temperature Controller   
         
The default temperature setting for this appliance installed without a temperature controller is 120º F (49º C).  If 
desired, the temperature setting can be changed to 140º F (60º C) by adjustment of a dip switch. 
In the SW1 bank of 8 dip switches, set dip switch 5 to ON to obtain 140º F (60º C) water temperature setting.  Set 
dip switch 5 to OFF (default) to obtain 120º F (49º C) water temperature setting. 
If a temperature controller is installed, then dip switch 5 has no effect on temperature settings. 
     WARNING 
DO NOT adjust the other dip 
switches unless specifically 
instructed to do so. 
  Setting the Sound Volume
 
(Voice Prompt)
                     
BC-100V  Press the “Sound Vol.” button to 
adjust the voice prompt volume.   
The default sound volume is set 
to Medium.  Each subsequent 
press of the button cycles 
through the volume levels in the 
order below. 
MC-100V  Press the “Function” button to 
adjust the voice prompt 
volume.  The default sound 
volume is set to Medium.  
Each subsequent press of the 
▲ or ▼ button cycles through 
the volume levels in the order 
below. 
Medium Volume 
(default) 
High Volume 
Off Volume  
(beep) 
Off Sound  
(no beep) 
Low Volume 
The MCC-91 controller is intended for commercial and hydronic 
applications only. If an MCC-91 controller is used in a residential 
dwelling for a hydronics application, a mixing valve must also be 
installed to limit the potable hot water temperature to a safe 
temperature. Water temperatures over 125º F (51º C) can cause severe 
burns or scalding. Refer to the Danger Alert on water temperatures. 
Rinnai shall not, in any event, be liable for damages resulting from such 
misuse or misapplication.  
**  MCC-91 Temperature Controller 
  These settings require the MCC-91 controller.  When the MCC-91 
controller is connected, these higher temperatures are available on all 
controller models in the system. Use of an MCC-91 controller in a 
residential dwelling will reduce the warranty coverage to that of a 
commercial warranty application. 
*  Re-setting the Maximum Temperature 
  These units have a default maximum temperature of 120º F (49º C) and 
an option to increase the maximum temperature to 140 ºF (60 ºC).  
Temperature settings from 125-140 ºF (52-60 ºC) are available by 
setting dip switch 6 to ON in the SW1 bank of 8 dip switches.      
  Temperature Controller Settings
                           
Switch No.
F
O
F
8
5
7
6
4
3
ON
1
2
Switch No.
F
O
F
8
5
7
6
4
3
ON
1
2
Maximum Temperature 
120º F (49º C)  