Pipe Sizing Procedure - Example 
  Gas Piping   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The gas supply must be capable of handling the entire gas load at the location.  Gas line sizing is based on gas 
type, the pressure drop in the system, the gas pressure supplied, and gas line type.  For gas pipe sizing in the 
United States, refer to the National Fuel Gas Code, NFPA 54.  For Canadian gas pipe sizing, refer to the Natural 
Gas and Propane Installation Code CAN/CSA B149.1.  The below information is provided as an example.  The 
appropriate table from the applicable code must be used. 
Pipe Size (inches) 
3/4 
1 1/4 
1 1/2 
10 
273 514 1060 
1580 
20 
188 353 726 1090 
30 
151 284 583 873 
40 
129 243 499 747 
50 
114 215 442 662 
60 
104 195 400 600 
70 
95 179 368 552 
80 
89 167 343 514 
90 
83 157 322 482 
100 
79 148 304 455 
125 
70 131 269 403 
150 
63 119 244 366 
175 
58 109 224 336 
200 
54 102 209 313 
Length  
Length  
Pipe Size (inches) 
1/2 3/4  1 1 
1/4 
10 
291 608 1150 
2350 
20 
200 418 787 1620 
30 
160 336 632 1300 
40 
137 287 541 1110 
50 
122 255 480 985 
60 
110 231 434 892 
80 
101 212 400 821 
100 
94 197 372 763 
125 
89 185 349 716 
150 
84 175 330 677 
175 
74 155 292 600 
200 
67 140 265 543 
Pipe Sizing Table - Natural Gas 
Pipe Sizing Table - Propane Gas 
Inlet Pressure:  less than 2 psi (55 inches W.C.) 
Pressure Drop:  0.3 inches W.C. 
Specific Gravity: 0.60 
Inlet Pressure:  11.0 inches W.C. 
Pressure Drop:  0.5 inches W.C. 
Specific Gravity: 1.50 
Schedule 40 Metallic Pipe 
Capacity in cubic feet per hour 
Schedule 40 Metallic Pipe 
Capacity in Thousands of BTU per Hour 
1.For some tables, you will need to determine the cubic feet per hour of gas required by dividing the gas input by 
the heating value of the gas (available from the local gas company).  The gas input needs to include all gas 
products at the location and the maximum BTU usage at full load when all gas products are in use.  
 
       Gas 
Input 
of 
all 
gas 
products 
(BTU 
HR) 
Cubic Feet per Hour (CFH) =  
         Heating 
Value 
of 
Gas 
(BTU 
FT 
2.Use the table for your gas type and pipe type to find the pipe size required.  The pipe size must be able to 
provide the required cubic feet per hour of gas or the required BTU/hour. 
Example:  The heating value of natural gas for your location is 1000 BTU/FT
3
.  The gas input of the RC98i is 
199,000 BTU/HR.  Additional appliances at the location require 65,000 BTU/hr.  Therefore the cubic 
feet per hour = (199,000 + 65,000) / 1000 = 264 FT
3
/HR.  If the pipe length is 10 feet then the 3/4 inch 
pipe size is capable of supplying 264 FT
3
/HR of natural gas.