Specifications 
Rinnai is continually updating and improving products.  Therefore, specifications are subject to change without 
prior notice. 
The maximum inlet gas pressure must not exceed the value specified by the manufacturer.  The minimum value 
listed is for the purpose of input adjustment. 
Model 
RC80i 
RC80e 
RC98i 
RC98e 
Minimum Gas Consumption Btu/h  
9,500 (NG)      10,300 (LPG) 
Maximum Gas Consumption Btu/h  
157,000 
 
199,000 
 
Hot water capacity (Min - Max) * 
0.4 - 8.0 GPM (1.5 - 30 L/min)  
 
0.4 - 9.8 GPM (1.5 - 37 L/min)  
 
Hot water capacity (45°F rise)  
6.6 GPM (25 L/min)  
 
8.5 GPM (32 L/min)  
 
Default Temperature Setting (no controller)  
120º F (49º C) 
Temperature Controller Default Setting 
104º F (40º C) 
Maximum Temp Setting (commercial **) 
185º F (85º C)   
Maximum Temp Setting (residential)  
see Temperature Ranges for more information 
Selectable at 120º F (49º C) or at 140º F (60º C)  
Minimum Temperature Setting  
98º F (37º C) 
Weight  
63.9 lb (29 kg)  
 
70.5 lb (32 kg)  
 
Energy Factor 
0.96 
0.94 
0.93 
Noise level  
50 dB  
Electrical 
Consumption  
Normal  
63 W 
44 W 
80 W 
59 W 
Standby  
2 W 
Anti-frost Protection  
220 W 
172 W 
220 W 
172 W 
By-Pass Control  
Electronic 
Minimum Gas Supply 
Pressure  
Natural Gas  
5.0 inch W.C. 
Propane  
8.0 inch W.C. 
Maximum Gas Supply 
Pressure  
Natural Gas  
10.5 inch W.C. 
Propane  
13.5 inch W.C. 
Type of Appliance  
Condensing, Tankless, Temperature controlled continuous flow gas hot water system.  
Operation  
With or without temperature controllers, mounted in kitchen, bathroom, etc.  
Approved Gas Type  
Natural Gas or Propane - Ensure unit matches gas type supplied at the installation location. 
Connections  
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT  
Ignition System  
Direct Electronic Ignition  
Electric Connections  
Appliance: AC 120 Volts, 60Hz. Temperature Controller: DC 12 Volts (Digital)  
Water Temperature Control  
Simulation Feedforward and Feedback.  
Water Supply Pressure  
Minimum Water Pressure: 50 PSI (Recommended 60-80 PSI for maximum performance)  
Maximum Water Supply Pressure  
150 PSI  
Remote Control Cable  
Non-Polarized Two Core Cable (Minimum 22 AWG) 
Energy Star Qualified 
Yes   
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. 
** for commercial and hydronic applications requiring higher temperatures