MAIN COMPONENTS 
1. Gas Control Unit 
1.1 Modulating Valve 
This device is used by the PCB to adjust the volume of gas to the burner in proportion to the 
volumetric flow rate of water in order to maintain a supply of constant temperature hot water 
amid changes in water flow rates and incoming temperatures. 
1.2 Change-over Solenoid Valves 
Additional solenoid valves are included to section the burner and stage the control in 3 
steps.  This gives the  Burner more steady combustion at the required capacity and allows 
the water heater to operate at very low flow rates and temperature rises.  
2. Flame Rod 
Monitors combustion characteristics inside the combustion chamber. If the flame fails, gas 
supply is stopped.  Works through rectification of the combustion flame.  An AC voltage is 
supplied to the flame rod.  Electrons can only pass from the rod to the flame, and never from 
the flame to the rod, so the resultant DC current is used to prove combustion.  When the DC 
current is present the burner has normal combustion, if the DC current is not present the unit 
shuts the solenoid valve.