Rinnai REU-VB2528WD-US 产品宣传页

下载
页码 2
RL75e (VB2528WD-US)    
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us 
Water Temperature Control 
Controller 
 
 
 
Controller Cable 
Safety Devices 
 
 
 
Clearances from Combustibles 
 
 
Clearances from Non-combustibles 
* 24 inches required for serviceability 
 
Min. / Max.  Gas Supply Pressure 
 
Manifold Gas Pressure (inches W.C.) 
(sea level) 
NOx 
Warranty 
Simulation feed forward and feedback 
MC-91-1US (included) 
Deluxe controller: MC-100V-1US (optional) 
Bathroom controller: BC-100V-1US (optional) 
MCC-91-1US (for commercial applications) 
Non-polarized two-core cable, minimum 22 AWG 
•  Flame failure - Flame Rod 
•  Boiling protection  
•  Combustion fan rpm check 
•  Over current - glass fuse  
•  Top of heater - 12 inches 
•  Front (Panel) - 24 inches 
•  Front (Exhaust) - 24 inches 
•  Top of heater - 2 inches 
•  Front (Panel) - 0 inches * 
•  Front (Exhaust) - 24 inches 
Natural Gas:  min 5”  W.C. 
max 10.5”  W.C. 
Propane Gas:  min 8”  W.C. 
max 13.5”  W.C. 
Natural Gas:  high fire 2.3”  W.C.  low fire 0.44”  W.C.  
Propane Gas:  high fire 4.2”  W.C.   low fire 0.93”  W.C. 
Meets California and Texas NOx Emission Rules 
Heat exchanger: 12 years* for residential and 5 years* for 
commercial and hydronic applications; (10 years* if used with the 
Rinnai Hydronic Furnace); all other parts 5 years*; labor 1 year; (* 3 
years if used as a circulating water heater within a circulation loop, 
when the water heater is in series with a circulation system and all 
circulating water flows through the water heater) 
DIMENSIONS 
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior 
notice. Local, state, provincial and federal codes must be adhered to prior to installation. 
WEIGHT: 51 LBS (23 KG) 
•  Remaining flame (OHS) 
•  Thermal fuse  
•  Automatic frost protection 
 
•  Back of heater - 0 inches 
•  Ground / bottom - 12 inches 
•  Sides of heater - 6 inches 
•  Back of heater - 0 inches 
•  Ground / bottom - 2 inches 
•  Sides of heater - 1/8 inch 
A
C
D
E
F
H
G
J
I
B
K
DIM DESCRIPTION 
in (mm) 
A Width 
14 
(355.6) 
B Depth 
9.9 
(251.1) 
Height - Unit 
22.9 (582) 
Distance between mounting 
holes 
25.0 (634.2) 
Hot Water Outlet - from wall 
3.8 (97.6) 
Hot Water Outlet - from center 
4.3 (110) 
Cold Water Inlet - from wall 
3.0 (76.6) 
Cold Water Inlet - from center 
1.1 (27) 
Gas Connection - from wall 
4.2 (105.6) 
Gas Connection - from center 
3.5 (89) 
 
From base to gas connection 
1.6 (40) 
From base to cold connection 
2.0 (50) 
 
From base to hot connection 
1.6 (41)