Only properly trained and qualified installers 
should install this appliance.  The warranty may 
be voided due to improper installation or 
installation by a non-qualified installer. 
Rinnai highly recommends all installers attend a 
product knowledge class.   
For information on a Rinnai Training Course or 
for questions on installation call 1-800-621-
9419. 
  General Instructions   
 
                             
•  This appliance must be installed by a state qualified 
or licensed contractor.  It is the responsibility of the 
person having the water heater installed to ensure 
the installing contractor has proper licenses and 
permits for installing water heaters in your location.  
Rinnai highly recommends that installers attend a 
product knowledge class to ensure customer 
satisfaction and warranty coverage.  Failure to 
comply with state and local codes pertaining to 
water heater installations may void the warranty. 
•  The RC80HPi (REU-KA2530FFUD-US) and 
RC98HPi (REU-KA3237FFUD-US) are not to be 
installed outdoors. 
•  The RC80HPe (REU-KA2530WD-US) and 
RC98HPe (REU-KA3237WD-US) are not to be 
installed indoors. 
•  A qualified installer or service technician should 
install the appliance, inspect it, and leak test it 
before use. 
•  The installation must conform with local codes or, in 
the absence of local codes, with the National Fuel 
Gas Code, ANSI Z223.1/NFPA 54
, or the Natural 
Gas and Propane Installation Code, CSA B149.1
•  The appliance, when installed, must be electrically 
grounded in accordance with local codes or, in the 
absence of local codes, with the National Electrical 
Code, ANSI/NFPA 70
, or the Canadian Electrical 
Code, CSA C22.1. 
•  The appliance and its appliance main gas valve 
must be disconnected from the gas supply piping 
system during any pressure testing of that system at 
test pressures in excess of 1/2 psi (3.5 kPa) (13.84 
in W.C.). 
•  The appliance must be isolated from the gas supply 
piping system by closing its individual manual 
shutoff valve during any pressure testing of the gas 
supply piping system at test pressures equal to or 
less than 1/2 psi (3.5 kPa) (13.84 in W.C.). 
•  Follow the installation instructions and those in Care 
and Maintenance for adequate combustion and 
ventilation air. 
•  The appliance should be located in an area where 
water leakage of the unit or connections will not 
result in damage to the area adjacent to the 
appliance or to lower floors of the structure.  When 
such locations cannot be avoided, it is 
recommended that a suitable drain pan, adequately 
drained, be installed under the appliance.  The pan 
must not restrict combustion air flow. 
•  The flow of combustion and ventilation air shall not 
be obstructed. 
•  This appliance is not suitable for use in an 
application such as a pool or spa heater that uses 
chemically treated water .  (This appliance is 
suitable for filling large or whirlpool bath tubs with 
potable water.) 
•  If a water heater is installed in a closed water supply 
system, such as one having a backflow preventer in 
the cold water supply line, means shall be provided 
to control thermal expansion. Contact the water 
supplier or local plumbing inspector on how to 
control thermal expansion. 
•  Should overheating occur or the gas supply fail to 
shut off, turn off the manual gas control valve to the 
appliance. 
•  Keep the air intake location free of chemicals such 
as chlorine or bleach that produce fumes.  These 
fumes can damage components and reduce the life 
of your appliance. 
•  Component damage resulting from chemical fumes 
is not covered under the Rinnai product warranty. 
     WARNING 
 
 
Do not use substitute materials. 
Use only parts certified with the appliance. 
Installation Instructions 
FOR INDOOR APPLICATIONS ONLY 
RC80HPi ............. REU-KA2530FFUD-US 
RC98HPi
 ............. REU-KA3237FFUD-US 
FOR OUTDOOR APPLICATIONS ONLY 
RC80HPe ............ REU-KA2530WD-US 
RC98HPe
 ............ REU-KA3237WD-US