Manual - Rinnai Condensing Water Heaters 
  How to Set the Temperature
                             
1.  If the water heater is off, press 
the ON/OFF button to turn on. 
While any hot water is being 
provided, the temperature setting can 
only be adjusted between 98º F    
(37º C) and 110º F (43º C). 
NOTICE 
          DANGER 
Hot water can be dangerous, especially for infants or children, the elderly, 
or infirm.  There is hot water scald potential if the thermostat is set too high. 
Water temperatures over 125º F (51º C) can cause severe burns or 
scalding resulting in death. 
Hot water can cause first degree burns with exposure for as little as: 
3 seconds at 140º F (60º C) 
20 seconds at 130º F (54º C) 
8 minutes at 120º F (48º C) 
Test the temperature of the water before placing a child in the bath or 
shower. 
Do not leave a child or an infirm person in the bath unsupervised. 
 
The priority can only be changed 
while no hot water is running. 
  Temperature Controller Settings
                           
This water heater will attempt to provide hot water at the temperature setting even when the water flow is varied 
or when more than 1 tap is in use.  The water heater can deliver water at only one temperature setting at a time.  
The available temperatures for a given model are provided below. 
Model 
Temperature Settings Available (ºF)  
RC80HPi 
RC80HPe 
RC98HPi 
RC98HPe 
98  100 102 104 106 108 110 115 120 
125
130
135
140
150
** 
160
** 
185
** 
Temp in Celsius  ºC 
37 
38 
39 
40 
41 
42 
43 
46 
49 
52 
54 
57   60 
66 
71 
85 
2.  Press the “Priority button” on the 
temperature controller.  The 
green Priority light will glow 
indicating that this controller is 
controlling the temperature and 
that the Rinnai water heater is 
ready to supply hot water. 
Check local codes for the maximum 
water temperature setting allowed 
when used in nursing homes, 
schools, day care centers, and all 
other public applications. 
NOTICE 
If a newly installed unit with a 
controller has not been powered for 
at least 6 hours then the temperature 
will return to the default setting of 
104º F (40º C) if power is interrupted. 
NOTICE 
There may be a variation between 
the temperature displayed on the 
temperature controller and the 
temperature at the tap due to 
weather conditions or the length of 
pipe to the water heater. 
NOTICE 
3. Press 
the 
▲ or ▼ buttons to 
obtain the desired temperature 
setting. 
 
All hot water sources are able to 
provide water at this temperature 
setting until it is changed again at 
this or another temperature 
controller.