Honeywell 2450HR 用户手册

下载
页码 10
www.honeywell.com/sensing
5
3100 Series
3100U Series
3106 Series
Description
hermetic
UL-approved hermetic
low level hermetic
Amperage
2.0 A/1.0 A/5.0 A/5.0 A
3.0 A resistive max.
100 mA/500 mA
Housing material
steel housing hermetically sealed with
glass-to-metal seal at terminal junction
steel housing hermetically sealed with
glass-to-metal seal at terminal junction
steel housing hermetically sealed with 
glass-to-metal seal at terminal junction
Operating temperature
-29 °C to 260 °C [-20 °F to 500 °F]
-29 °C to 260 °C [-20 °F to 500 °F]
-29 °C to 204 °C [-20 °F to 400 °F]
Environmental exposure range
-62 °C to 288 °C [-80 °F to 550 °F]
-62 °C to 288 °C [-80 °F to 550 °F]
-62 °C to 260 °C [-80 °F to 500 °F]
Dielectric strength
MIL-STD-202, Method 301; 1250 Vac 60 Hz 
- Terminal to Case
MIL-STD-202, Method 301; 1250 Vac 
60 Hz - Terminal to Case
MIL-STD-202, Method 301; 1250 Vac 
60 Hz - Terminal to Case
Insulation resistance
MIL-STD-202, Method 302; Cond. B - 500 
MOhm - 500 Vdc applied
MIL-STD-202, Method 302; 50 MOhm 
or MIL-STD-202, Method 302; Cond. 
B - 500 MOhm - 500 Vdc applied
MIL-STD-202, Method 302; Cond. B - 
500 MOhm - 500 Vdc applied
Contact resistance
MIL-STD-202, Method 307; 0.050 Ohm 
MIL-STD-202, Method 307; 0.050 Ohm 
max.
MIL-STD-202, Method 307; 0.050 
Ohm
Hermetic seal
MIL-STD-202, Method 112; 
Cond. 1 x 10-5 
MIL-STD-202, Method 112; 
Cond. 1 x 10-5 
MIL-STD-202, Method 112; 
Cond. 1 x 10-5
Moisture resistance
MIL-STD-202, Method 106
MIL-STD-202, Method 106
MIL-STD-202, Method 106
Shock
N/A
N/A
N/A
Vibration
N/A
N/A
N/A
Thermal shock
N/A
N/A
N/A
Salt spray
N/A
N/A
N/A
Acceleration
N/A
N/A
N/A
Precision 
Thermostats