Lux Products CH200SA 用户手册

下载
页码 4
2
Heating Systems
  * If replacing a Honeywell TM-11,
     tape off wire “R”; connect wire “B”
     to terminal “RH.”
** If replacing a Honeywell thermostat
     with a clock wire “C,” tape off wire “C”
Cooling Systems
* If both Y and C wire are 
present, tape  off “C” wire.
Heating/Cooling Systems
4- or 5-Wire with One Transformer
* If both Y and C wire are 
present, tape off “C” wire.
Heating/Cooling Systems
5-or 6- Wire with Two Transformers
* If both Y and C wire are 
present, tape off “C” wire.
FAN RELAY
      COOLING COMPRESSOR
           HEATING CONTROL
                HEATING TRANSFORMER
                       COOL TRANSFORMER
G
Y
W RH RC
G
5
4
RC
V
R*
H
W
F
RH
Tape Off **
C
Tape Off
TC
G
Y
W RH RC
Y
C
G
F
RC
R
V
*
FAN RELAY
      COOLING COMPRESSOR
           HEATING CONTROL
                HEATING TRANSFORMER
                       COOL TRANSFORMER
FAN RELAY
      COOLING COMPRESSOR
           HEATING CONTROL
                HEATING TRANSFORMER
                       COOL TRANSFORMER
G
Y
W RH RC
C
Y
G
F
W
V
R
RC
Tape Off
TC
*
FAN RELAY
      COOLING COMPRESSOR
           HEATING CONTROL
                HEATING TRANSFORMER
                       COOL TRANSFORMER
G
Y
W RH RC
Y
C
G
F
W
4
A
RH
Tape Off
TC
V
R
RC
*
WIRING DIAGRAMS