These designs comply with the current version of the American National 
Standard for Gas Water Heaters, Volume III, ANSI Z21.10.3 / CSA 4.3 as 
an  automatic  circulating  tank  water  heater,  and  automatic  storage  water 
heaters.
Detailed installation diagrams are found in this manual.  These diagrams will 
serve to provide the installer with a reference for the materials and methods 
of piping necessary.  It is highly essential that all water, gas piping and wiring 
be installed as shown on the diagrams.
Particular attention should be given to the installation of thermometers at the 
locations indicated on the diagrams as these are necessary for checking the 
proper functioning of the heater.
In  addition  to  these  instructions,  the  equipment  shall  be  installed  in  
accordance  with  those  installation  regulations  in  force  in  the  local  area 
where  the  installation  is  to  be  made.  These  shall  be  carefully  followed 
in  all  cases.  Authorities  having  jurisdiction  should  be  consulted  before 
installations are made.
In the absence of local codes, the installation must comply with the current 
editions  of  the  National  Fuel  Gas  Code, ANSI  Z223.1/NFPA  54  and  the 
National Electrical Code, NFPA 70 or CAN/CSA-B149.1, the Natural Gas and 
Propane Installation Code and CSA C22.1, the Canadian Electrical Code. 
All documents are available from the Canadian Standards Association, 8501 
East Pleasant Valley Road, Cleveland, OH 44131. NFPA documents are 
also available from the National Fire Protection Association, 1 Batterymarch 
Park, Quincy, MA 02269.
FOREWORD
HIGH EFFICIENCY AHCG3/HCG360T120 thru AHCG3/HCG3100T250 ROUGH-IN-DIMENSIONS
Table 1.  RECOVERY CAPACITIES - NATURAL GAS / L.P.
 
    
    
    
           
 
   
  
 Approx. 
       TEMPERATURE RISE - DEGREES °F - GALLONS PER HOUR  
  AHCG3/    Input 
Gas 
 Gallon
  HCG3 
BTU/Hr.  Usage  Capacity 
30 
40 
50 
60 
70 
80 
90 
100  110  120  130  140
  60T120  120,000  nat/lp 
60 
461  345  276  230  197  173  154  138  126  115  106  99
 100T150  150,000  nat/lp 
100 
576  432  345  288  247  216  192  173  157  144  133  123
 100T199  199,900  nat/lp 
100 
767  575  460  384  329  288  256  230  209  192  177  164
 100T250  250,000  nat/lp 
100 
960  720  576  480  411  360  320  288  262  240  221  206 
 
   
    
    
           
  AHCG3/ 
  Gas 
   Liter 
Approx.         
 TEMPERATURE RISE - DEGREES C - Liters PER HOUR     
  HCG3 
kW-Hr 
Usage  Capacity 
17 
22 
28 
33 
39 
44 
50 
56 
61 
67 
72 
78
  60T120 
35 
nat/lp 
227 
1744  1308  1046  872  747  654  581  523  476  436  402  374
  100T150 
44 
nat/lp 
379 
2179  1635  1308 1090  934  817  726  654  594  545  503  467
  100T199 
58 
nat/lp 
379 
2904  2178  1743 1452 1245 1089  968  871  792  726  670  622
  100T250 
73 
nat/lp 
379 
3632  2724  2179 1816 1557 1362  1211  1090  991  908  838  778
Recovery capacities are based on 95% thermal efficiency.
GAS VALVE PIPING
AHCG3/HCG360T120
1/2" NPT
AHCG3/HCG3100T150 thru 100T250
3/4" NPT