Instructions to Installer
1. Installer must leave instruction manual with owner after installation.
2. Installer must have owner fill out and mail warranty card supplied with
unvented room heater.
3. Installer should show owner how to start and operate unvented room
heater.
Always consult your local Building Department regarding regulations,
codes or ordinances which apply to the installation of an unvented room
heater.
This appliance may be installed in an aftermarket* permanently located,
This appliance may be installed in an aftermarket* permanently located,
manufactured (mobile) home, where not prohibited by state or local
codes.
*Aftermarket: Completion of sale, not for purpose of resale, from the
*Aftermarket: Completion of sale, not for purpose of resale, from the
manufacturer.
This appliance is only for use with the type of gas indicated on the rating
This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases.
General Information
This appliance is design certified in accordance with American National
General Information
This appliance is design certified in accordance with American National
Standards Institute Z21.11.2 by the Canadian Standards Association
Laboratories as an Unvented Room Heater and shall be installed
according to these instructions.
Any alteration of the original design, installed other than as shown in
Any alteration of the original design, installed other than as shown in
these instructions or use with a type of gas not shown on the rating plate
is the responsibility of the person and company making the change.
WARNING: This appliance is equipped for (natural gas or
propane) gas. Field conversion is not permitted.
Important
All correspondence should refer to complete Model Number, Serial
All correspondence should refer to complete Model Number, Serial
Number and type of gas.
Well Head Gas Installations
Some natural gas utilities use “well head” gas. This may affect the
Well Head Gas Installations
Some natural gas utilities use “well head” gas. This may affect the
Btu output of the unit. Contact the gas company for the heating value.
Contact the manufacturer or your gas company before changing spud/
orifice size.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment or
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment or
accessories and repair and servicing of equipment shall be performed
only by a qualified agency. The term “qualified agency” means any
individual, firm, corporation, or company that either in person or through
a representative is engaged in and is responsible for (a) the installation,
testing, or replacement of gas piping or (b) the connection, installation,
testing, repair, or servicing of equipment; that is experienced in such
work; that is familiar with all precautions required, and that has complied
with all the requirements of the authority having jurisdiction.
State of Massachusetts: The installation must be made by a licensed
plumber or gas fitter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental
Sellers of unvented propane or natural gas-fired supplemental
room heaters shall provide to each purchaser a copy of 527 CMR
30 upon sale of the unit.
In the State of Massachusetts, unvented propane and natural
In the State of Massachusetts, unvented propane and natural
gas-fired space heaters shall be prohibited in bedrooms and
bathrooms.
The installation must conform with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA54.*
*Available from the American National Standards Institute, Inc., 11 West
*Available from the American National Standards Institute, Inc., 11 West
42nd St., New York, N.Y. 10036.
High Altitudes
For altitudes/elevations above 2,000 feet (610m) ratings should be
High Altitudes
For altitudes/elevations above 2,000 feet (610m) ratings should be
reduced at the rate of 4 percent for each 1,000 feet (305m) above sea
level. Contact the manufacturer or your gas company before changing
spud/orifice size.
INTRODUCTION
SPECIFICATIONS
Model
SR-6
SR-10
SR-18
SR-30
Input BTU/HR (KW/H) Five Plaques
—
—
—
30,000 (8.8)
BTU/HR (KW/H) Three Plaques
—
—
18,000 (5.3)
18,000 (5.3)
BTU/HR (KW/H) Two Plaques
—
—