Multiquip LS600P 用户手册

下载
页码 88
page 32 — MaYCO LS600p CONCReTe pUMp • OpeRaTiON MaNUaL — Rev. #0 (05/13/13) 
SEtuP
Location of pump
1.  Place the pump in the best location on the site to pump 
concrete efficiently.
2.  Lay down the hose in the shortest distance possible.
Rear Stabilizer Jacks
To reduce excessive vibration and rocking of the pump, set 
the rear stabilizers as follows:
1.  Locate both the left and right rear stabilizer jacks 
(Figure 16).
Figure 16. Locating Rear Stabilizer Jacks
2.  Remove the cotter pin (Figure 17) from the handle tee 
bolt eye, and then pull the handle tee to release the 
stabilizer jack.
Figure 17. Rear Stabilizer Jack
  WaRNiNg
NeveR place feet under jack while operating.
ALWAYS retract rear stabilizer jacks prior to towing.
ALWAYS retract rear stabilizer jacks prior to servicing 
to relieve load (working pressure).
REAR
STABILIZER
JACKS
3.  Position both rear stabilizers jacks on firm (not loose) 
level ground (Figure 18).
Figure 18. Rear Stabilizer Stand Deployment
4.  Align the hole on the stabilizer jack with the hole on 
the frame body and insert handle tee bolt.
5.  Insert the cotter pin into handle tee bolt eye to lock the 
stabilizer jack.
Hydraulic Rear Stabilizer Jacks (Optional)
If your pump comes equipped with hydraulic rear stablizers 
(Figure 19), they can be controlled as follows: 
1.  Push down the middle control lever  to extend the right 
hydraulic rear stabilizer.
Figure 19. Control Levers for Hydraulic Rear 
Stabilizers
2.  Push up the middle control lever to retract the right 
hydraulic rear stabilizer.
3.  Push down the rightmost control lever to extend the 
left hydraulic rear stabilizer.
4.  Push up the rightmost control lever to retract the left 
hydraulic rear stabilizer.
INCORRECT
CORRECT
RIGHT HYDRAULIC
STABILIZER JACK
LEFT HYDRAULIC
STABILIZER JACK
MIDDLE CONTROL LEVER
(CONTROLS RIGHT
HYDRAULIC STABILIZER)
RIGHTMOST
CONTROL LEVER
(CONTROLS LEFT
HYDRAULIC
STABILIZER)