Operating Instructions and Parts Manual  
JSU50
 
www.waynepumps.com
Installation
 (Continued) 
9.   Slope horizontal lines up toward 
pump a minimum of 1/4" per foot. 
this will prevent trapping air in the 
lines.
PRe-CHaRGeD tanK (See FIGuRe 5)
a pre-charged water tank stores air 
and water in separate compartments, 
separated by a flexible bladder. the 
barrier prevents the air from being 
absorbed into the water. the bladder 
design also allows the water to be 
acted on by higher pressures for longer 
periods than a conventional tank. 
Pre-charged tanks have roughly twice 
the usable capacity of a conventional 
tank with equal volume. the air 
pressure in a pre-charged tank must be 
checked periodically to insure it is at an 
acceptable level (See Maintenance).
1.   Shut off power to pump. Disconnect 
and lock out power source.
2.   Drain the tank. open faucet nearest 
the tank.
Make sure the pump has adequate 
ventilation. the surrounding 
temperature should not exceed 100˚F 
(38˚C) or nuisance tripping of thermal 
overload protector on the motor may 
occur.
PUMP PIPING INSTallaTION
use new pipe for best results. Iron, 
copper or PVC pipe may be used. 
to avoid strain on the pump when 
using iron or copper pipe, provide 
independent supports for both suction 
and discharge piping near the pump. 
Minimize use of elbows and fittings 
to reduce friction loss. Refer to the 
friction loss chart (page 5) for specific 
information. Increase diameter of 
suction or discharge piping if length is 
over 50 feet.
SUCTION PIPING
 
Install foot valve 
  or strainer screen 
over intake of suction piping.
never use pipe smaller than 1-1/4” 
diameter for suction piping. Keep 
suction pipe free of air leaks. For 
horizontal runs, lay pipe from the water 
source so the upward slope is at least 
1/2" per foot. this eliminates trapped 
air. the threaded inlet of the pump is 
1-1/4" nPt.
 
Do not install 
  suction piping near 
swimming areas.
DISCharGE PIPING (fIGUrE 2) 
Install a 3/4” pipe cross (sold separately) 
in the pump discharge. Plug top of 
pipe cross with 3/4” nPt pipe plug (sold 
separately). Insert tank tubing into side 
opening of pipe cross. Insert pipe into 
remaining side opening for connection 
to home water supply line.
CONNECTION TO waTEr TaNK
ConVentIonal tanK (See FIGuReS 3 
& 4)
a conventional water tank stores 
water and pressurized air in the same 
compartment. When full, the tank 
contains approximately 2/3 water and 
1/3 compressed air. this type of tank 
requires an air volume control, which 
automatically replaces air lost due to 
leak or absorption into the water.
1.   Shut off power to pump. Disconnect 
and lock out power source.
2.   Drain the tank. opening faucet 
nearest tank is recommended.
3.   Insure tank is secured to the floor or 
base.
4.   Bolt pump to the floor or the 
mounting bracket on tank.
5.   Install air volume control on tank.
6.   Connect the tube from the air 
volume control to the front 1/8" 
nPt opening on the side of the 
pump. Connections must be tight. 
leaks will cause the pump not to 
prime and/or the tank to become 
waterlogged.
7.   Install a valve and an isolator hose 
between the tank and the house 
plumbing. this will reduce the noise 
level of the pump system and aid in 
servicing.
8.   Provide a hose bib (faucet) at the 
lowest point in the system to drain 
the system for service or storage.
to 
WateR 
lIne
to  
Well  
oR 
CISteRn
figure 1 - Pipe Installation
PReSSuRe 
SWItCH
PRIMe PluG
figure 3 - Shallow well Pump with 
Conventional horizontal Tank
Inlet
DRaIn FIttInG
aIR VoluMe 
ContRol 
tuBInG
aIR VoluMe 
ContRol
figure 4 - Shallow well Pump with 
Conventional Vertical Tank
PRIMe 
PluG
Inlet
DRaIn 
FIttInG
aIR VoluMe 
ContRol tuBInG
aIR VoluMe 
ContRol
PIPInG to HoMe 
WateR SySteM
PRIMe 
PluG
PIPe CRoSS
tanK 
tuBInG
figure 2
aIR VoluMe ContRol 
ConneCtIon