VENT INSTALLATION 
Figure 7 - Combustible Clearances for Vent Pipe 
A Minimum of 4" Clearance to the Top Is 
Required Along Horizontal Length of Pipe until 
Flue Pipe Goes Through Nearest Wall. 
WARNING
This fireplace must be vented to the outside. The venting system must NEVER be attached 
to a chimney serving a separate solid
-fuel burning appliance. Each gas appliance must 
use a separate vent system. Do not use common vent systems. 
WARNING
Horizontal sections of this vent system require 
a minimum clearance of 
4
" from the top of 
the  pipe  and  1"  minimum  to  the  sides  and 
bottom. Vertical sections of this system require 
a minimum of 1" clearance to combustible 
materials on all sides of the pipe. 
WARNING
1" Clearance Is Acceptable 
at the Outside Wall. 
6
6
4
" minimum
1
" minimum
2'
 pipe
Basic Horizontal Vent
Installation