Mastic 92P 用户手册

下载
页码 42
26                                                                                                                                                       
L100001                                                                                                                                                                            
27
�� �
����
��
FIREPLACE INSTALLATION 
A listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 
1
/
8
" NPT pressure tapping 
point should be installed upstream of the appliance. See Figure 33.
IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for 
turning on or shutting off the gas to the fireplace. 
Check your building codes for any special requirements for locat-
ing equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male threads. This will prevent 
excess sealant from going into pipe. Excess sealant in pipe could 
result in clogged burner system valves.
We recommend that you install a sediment trap/drip leg in supply 
line as shown in Figure 33. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between 
fuel supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps 
moisture and contaminants. This keeps them from going into the burner system gas controls. If sediment trap/drip leg is not 
installed or is installed wrong, burner system may not run properly. 
Figure 33 - Gas Connection 
Tee Joint
Pipe Nipple
Cap
Approved Flexible Gas 
Line 
CSA Design-Certified Equipment Shutoff Valve 
with 
1
/
8
" NPT Tap
Sediment Trap/Drip Leg 
Natural Gas
From Gas Meter 
(5" W.C. to 10.5" W.C. Pressure)
Propane/LP
From External Regulator 
(11" W.C. to 13" W.C. Pressure)
NOTE : The gas line connection may be made using 
1
/
2
" rigid tubing or an approved flex connector. Since some 
municipalities have additional local codes it is always best to consult your local authorities and the current edition 
of the National Fuel Gas Code ANSI.Z223.1, NFPA54. In Canada CAN/CGA-B149 (1 or 2) Installation Code. 
Only persons licensed to work with gas piping 
may make the necessary gas connections to 
this appliance. 
WARNING
A manual shutoff valve must be installed upstream 
of  the  appliance.  Union  tee  and  plugged 
1
/
8
NPT  pressure  tapping  point  should  be  installed 
upstream of the appliance. See Figure 33.
CAUTION
Use pipe joint sealant that is resistant to liquid 
petroleum (LP) gas.
CAUTION