Aerada 1000/1100 Series 
Installation
12 
5/21/08 Bradley 
Corporation • 215-1628 Rev. A; EN  08-201
CARE AND MAINTENANCE INSTRUCTIONS
The following instructions are described in this section:
• Activating Cleaning Mode
•  Replacing Battery
•  Cleaning or Replacing Inlet Filter
•  Adjusting Water Temperature (Internal Mixer)
•  Adjusting Hot Water Limiter (External Mixer)
•  Cleaning or Replacing Aerator
 
Activating Cleaning Mode
In order to set the cleaning mode, the faucet needs to be have been set once into 
the “Manual Setting” mode. See “Manual Setting” instructions. When cleaning 
mode is activated, the faucet will be inoperable for 90 seconds.
1  Fully cover sensor with hand, until water fl ow stops. (This takes approximately 
5 seconds.)
2  Remove hand.
Result:  Cleaning Mode is now activated.
Replacing Battery
A traditional lavatory faucet is shown as an example. These instructions apply to 
all DC models.
 
Prerequisites
• Battery is low (LED is lit)
•  New 6 V Lithium battery (CR-P2) is required
1  Remove shut-off screw
2  Remove mixer handle (for faucets with external mixer only)
3  Remove housing vertically.
4  Remove used battery from battery holder and recycle.
5  Insert 
new 
battery. 
      
> LED lights up for 1 second
6  Mount housing vertically.