Step 1: Mount Extension to alcove wall
1. Mark a level line flush with the
top of the Express
®
MG-Series
bowl (see Figure 1a).
2. From that line, measure down
1" and mark another level line.
This line will be used to locate
the top of the Extension
brackets.
3. Measure the opening between
the Express
®
Lavatory System
MG-Series and the alcove. If
the Extension does not fit
properly within the opening,
trim the flat (wall) end of
Extension to fit using a
tablesaw with a carbide tipped
blade to trim the Extension)
(see Figures 1a and 1b).
4. Attach the support brackets to the Extension (see Figure 1a).
5. Place and level the Extension into the alcove or between the bowls and, using the brackets as a
template, mark the hole locations for the wall anchors and/or hole locations on the Express
®
MG-Series bowl.
NOTE: Extensions 22" long or less do not require mounting brackets (P/N 140-814) or wall anchors
for mounting.
6. Drill 1/4”-20 clearance holes into the bowls at the hole locations marked in procedure #5. Drill
holes for 1/4”-20 wall anchors (supplied by installer) and insert the anchors into the wall.
7. Using the hardware supplied, attach the Extension to the wall or Express
®
MG-Series bowl (see
Figures 1a, 1b and 1c).
Figure 1a
Figure 1b
Figure 1c