Pre-Installation Information
Barrier-free and ADA compliant - standard height mounting 
The SS-3/AST/STD Express® Lavatory System must have a rim height of 34" above finished
floor to be compliant with Americans with Disabilities Act (ADA). When mounted at 34" rim
height, the Express® meets ADA, ANSI and UFAS requirements for barrier-free clearances,
reaches and controls. Always check local codes and ordinances for compliance.
Barrier-free and ADA compliant - juvenile height mounting 
The SS-3/AST/JUV Express® Lavatory System is compliant with Americans with Disabilities
Act (ADA) Accessibility Guidelines for Buildings and Facilities: Building Elements Designed for
Children's Use; Final Rule.
Pushbutton and air valve
Each sprayhead is controlled by a pushbutton air valve, enabling each user to activate a single flow
of water. Air valves use 0.5 gpm for a ten-second duration, meeting the ANSI/ASHRAE/IES
90A-1980 Standard.
Supplies required for installation:
• (8) 3/8" wall anchors, bolts and washers to mount frame and bowl to wall
(minimum pull-out rating of 1,000 lbs.)
• 1/2" NPT hot and cold supply piping
• 1-1/2" NPT drain piping