Nortel Networks BCM 1000 用户手册

下载
页码 86
Chapter 2 Documentation updates for BCM 4.0
15
BCM 4.0 for BCM1000 Installation and Maintenance Guide Addendum
Page 110, Shutting down the system
The procedure about how to shut down the system should be replaced with the following section.
Performing a system shutdown
If there is a need to perform maintenance, the system may already be powered down. If this is the 
case, proceed to 
If the system is still operating, perform the following procedures:
To shut down the system software
1
Check for a recent backup of the BCM system programming. 
2
If there is no recent backup, use Element Manager to back up the system data. For information 
about backing up the system data, refer to the BCM 4.0 Administration Guide.
3
In Element Manager, from the Administration tab, click the Utilities folder to expand it.
4
From the Utilities folder, select Reset.
5
Click Shutdown System to prepare the system for power disconnect. 
This action will stop all services. All Element Manager sessions will be disconnected from the 
system. The BCM system can be restored to service only by powering the BCM system off and 
back on again. 
6
Click Ok.
The progress update dialog box appears and the BCM system begins the shutdown process.
When the shutdown process is complete, the final warning dialog box appears, and the LEDs 
enter the flashing state.
7
Click Ok to disconnect Element Manager.
When the shutdown Element Manager is disconnected, the system gives an audible beep. The 
LEDs remain in the flashing state until the hardware is shutdown (see 
If the system hardware is not shutdown within about 15 minutes, it automatically boots up 