Eureka 4380 Series 用户手册

下载
页码 11
11
Use 15 watt replacement light bulb, part number 48815.
HOW TO MAINTAIN 
(continued)
How To Change Light Bulb 
(only for models with a headlight)
NOTE:  Turn off the power switch and disconnect the 
electrical cord before changing light bulb.
1.   Lower handle. Remove two screws from lens cover.
2.   Pull lens cover from cleaner.
3.   Pull light bulb and socket toward front.
4.   Push light bulb into socket; turn to release.
5.   Place new light bulb into socket; turn to secure.
6.   Push light bulb and socket back so bulb will not touch lens 
cover.
7.   Replace lens cover.
8.   Secure with two screws.
Problem Solving
NOTE: Turn off the switch and unplug electrical cord before servicing.
Motor will not start
Motor suddenly 
stops 
Does not clean the 
carpet or floor. 
 
No suction at the 
end of the hose.
Headlight not 
working.
Noise from the 
brush roll area.
Cleaner is hard to 
push.
Cleaning height 
knob will not turn.
Missing parts.
Questions?
Push plug securely into outlet.
Try another outlet.
Check circuit breaker.
Refer to page 3 & 5.
Clean or replace the filter(s). Hint: If picking up fine dust, the 
filter may not look dirty but a fine substance tends to reduce 
suction when it blocks the airflow through the filter(s).
  
Be sure hose adapter inserts into cyclonic cassette.
Be sure the cyclonic cassette is properly seated into the cassette 
body. See page 4.
Empty cyclonic cassette. Note: There are two chambers in the 
cyclonic cassette. The chamber with the screen will fill much 
faster than the chamber with the cone. This is normal, when the 
chamber with the screen is full, empty cyclonic cassette, do not 
wait till the chamber with the cone is full. See page 7.
Replace a cut, loose or out of shape belt.
Snap the belt cap inside the hood if it comes loose.
Clean hair and thread from bristles and end cap area.
Replace brush roll if bristles are worn.
Remove any clogs from the hose that restrict the airflow. Check 
short hose in the base and long hose. Refer to page 9.
Hose adapter has to seat inside the cyclonic cassette. Hint: Put 
the hose in place before attaching the handle. The handle 
secures the hose.
Clean or replace the filter(s). Hint: If picking up fine dust, the 
filter may not look dirty but a fine substance tends to reduce 
suction when it blocks the airflow through the filter(s).
Remove any clogs from the hose that restrict the airflow. Check 
short hose in the base and long hose. Refer to page 9.
Replace light bulb.
Remove hood and clean debris or items from the brush roll area.
Replace a cut, loose or out of shape belt.
Put handle in operating position. Tilt the cleaner back to raise the 
front wheels off the floor. Then turn the knob to a higher setting.
Replace a cut, loose or out of shape belt.
Hint: Put handle in operating position. Tilt the cleaner back to 
raise the front wheels off the floor. Then turn the knob.
Call 1-800-438-7352 between 8:00 a.m. and 4:45 p.m., central 
standard time, Monday through Friday. Know the model and 
serial numbers when you call.
  
Call 1-800-282-2886 8 a.m. to 7:30p.m., (CST), Monday -     
Friday and 10 a.m. to 6:30 p.m. (CST) Saturday. Know the     
model and serial numbers when you call.
PROBLEM�
CAUSE�
SOLUTION
Electric Plug
Thermal Cut Off 
Filters
Cyclonic Cassette
Belt 
Belt Cap
Brush Roll
Hose
Hose Adapter
Filter(s)
Hose
Light Bulb
Brush Roll
Belt
Cleaner Height Setting
Belt
Cleaner Height Setting