Troubleshooting
Problem
Possible Cause 
Solution
Membrane expended 
Replace Membrane module. Contact your 
local Hague dealer
Membrane attack by chlorine (Not applicable 
to CTA element) 
Precarbon may be exhausted. Replace with a 
new cartridge and a new membrane 
Check valve failure 
Replace check valve. Contact your local 
Hague dealer 
Insufficient brine flow rate-screen of flow 
restrictor pressure/control plugged 
Replace or flush out screen and /or flow 
restrictor/pressure control. Contact your local 
Hague dealer 
A clogged pre-filter creates pressure drop 
and low brine flow 
Replace the clogged pre-filter cartridge with a 
new one 
Feed pressure too low 
See
Filter Specifications chart to verify 
minimum feed pressure for your model 
Insufficiently flushed Carbon Post-Filter 
cartridge
Flush Carbon Post-Filter with product water. 
One or two tanks should be sufficient 
High product water TDS 
Increase in feed water TDS 
Contact your local Hague dealer 
Feed water shut off 
Turn on your feed water valve 
Low feed pressure 
See
Filter Specifications chart to verify 
minimum feed pressure for your model 
A pre-filter cartridge clogged 
Replace the clogged pre-filter cartridge with a 
new one
Screen in flow restrictor/pressure control 
plugged 
Replace or flush out screen and/or flow 
restrictor/pressure control. Contact your local 
Hague dealer 
Membrane fouled 
Determine and correct cause; replace 
membrane. Contact your local Hague dealer 
Product check valve stuck 
Replace check valve 
Tank overpressurized 
Adjust air pressure between 5 and 7 PSI 
Over use 
Contact your local Hague dealer 
Tank valve off 
Open tank valve 
No water or not enough 
water
Stalled permeate pump 
Confirm both product and reflect flow into and 
out of permeate pump. Replace pump if 
necessary 
Low water production 
See “No water or not enough water” 
Tank lost air precharge 
Adjust air pressure between 5 and 7 PSI valve 
stem and tighten
Tank diaphragm slipped Replace 
tank 
Carbon Post-Filter clogged 
Replace Carbon Post-Filter cartridge 
Low flow rate from 
spigot
Tank valve partially closed 
Open tank valve 