GE 263 用户手册

下载
页码 44
28 
Level II Programming
Rev A
Level II Programming
Level II program parameters are those parameters used to fine-tune a 
conditioners operation. These are accessible by pressing and holding the 
UP and DOWN buttons until the display goes blank. Then release the 
buttons. Calendar Override is the first Level II parameter displayed. Level II 
program parameters include:
268 Conditioner Operation Type
263 Filter Operation Type
CALENDAR OVERRIDE
CALENDAR OVERRIDE
SALT AMOUNT 
REGEN SU
CAPACITY K GRAIN
REGEN MO
HARDNESS GPG
REGEN TU
SELECT LANGUAGE 
REGEN WE 
CLOCK MODE
REGEN TH
UNITS OF MEASURE
REGEN FR
INJECTOR SELECTION*
REGEN SA
BACKWASH 1 
CAPACITY GAL
SLOW RINSE 
SELECT LANGUAGE
FAST RINSE 1 
CLOCK MODE
BACKWASH 2 
UNITS OF MEASURE
FAST RINSE 2 
BACKWASH
OPERATION TYPE 268*
FAST RINSE
SERVICE INTERVAL
OPERATION TYPE 263*
CHLORINE GENERATOR
SERVICE INTERVAL
CHLORINE GENERATOR
*View only.
Level II parameters will, in almost all cases, be preset to meet your 
configuration needs. The predefined system number will preprogram all of 
the Level II parameters to the selected default values. 
Setting the Calendar Override
Calendar Override allows the programmer to set the maximum days 
between regenerations. A setting of 0 (zero) means the calendar 
override is disabled. To change the calendar override, press the SET 
button while the words “CALENDAR OVERRIDE" appear on the banner 
display. The blinking digit can be changed to the desired numbers of 
days. To lock in the parameter, press the SET button.
WARNING:  
Setting days between regeneration to zero will cause the 
system to not regenerate.  This setting is used for selecting regeneration 
on specific days or to use with a remote regeneration input.  See below.