UltraMax System Configurations
43
Rev A
UltraMax System Configurations
Upon initial start-up of the UltraMax controller, the software will request a 
pre-determined model number. This model number populates the default 
values within the controller, allowing for quick and easy set-up of the 
software without entering several levels of data. The table below shows 
the pre-determined model numbers for the controller and the associated 
primary valve functions for each number.
Use the UP and DOWN buttons to scroll through the available model 
numbers. Press the SET button to select the number and move to the 
standard programming value.
Controller Reset:
If the incorrect model number is accidentally selected for the controller, 
you can easily reset the controller to the factory default mode. When the 
controller is in normal operating mode showing the time of day, perform 
the following steps.
1. Press the DOWN and SET buttons simultaneously and hold for 5 
seconds.
2. After 5 seconds the controller will go blank. Release the buttons and 
the controller will scroll "MODEL NUMBER " and the selected model will 
be displayed.
3. If the number is correct, wait 30 seconds and the controller will 
automatically go back to normal operation mode.
4. If the model number is incorrect, press and hold the SET button for 5 
seconds. This will default the controller back to the factory default 
setting. The controller will scroll "MODEL NUMBER " and the factory 
model number will begin flashing, meaning it can be changed. USe the 
UP or DOWN buttons to scroll to the correct model number. Select that 
number by pressing the SET button.
Model 
Number
System Description
Operation 
Type
System 
Capacity
Salt 
Amount
10
1.0 cu ft Conditioner
268 Valve
15 Kgrains
3.0 lbs
15
1.5 cu ft Conditioner
268 Valve
23 Kgrains
4.5 lbs
20
2.0 cu ft Conditioner
268 Valve
31 Kgrains
6.0 lbs
93
Generic Filter
263 Valve
N/A
N/A
98
Generic Conditioner
268 Valve
25 Kgrains
9.0 lbs