Atlas 240 Series 用户手册

下载
页码 8
4
598-1094-04
70 ft.
(21 m)
8 ft. 
(2.4 m)
240°
 
Maximum Range 
Maximum
 
 
Coverage Angle
100 ft.
(30.5 m)
Boosted
Motion
Motion
NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming 
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.
  Loosen the clamp screw in the 
sensor  ball  joint  and  gently 
rotate the sensor.
  Walk  through  the  coverage 
area  noting  where  you  are 
when the lights turn on (also, 
the LED will flash several times 
when motion is detected). Move 
the sensor head up, down, or 
sideways to change the cover-
age area. 
Keep the sensor at
least 1" (25 mm) away from
the bulbs.
  Adjust the RANGE as needed. 
RANGE  set  too  high  may 
increase false triggering.
 
Secure the sensor head by
tightening the clamp screw.
 
Do not overtighten the screw.
  Set the amount of TIME you want the lights to stay 
on after motion is detected (1, 5, or 20 minutes).
  Set the Dual Light Level switch to the amount of 
time after dusk you want the lights on at low level 
(Off, 3, 6 Hrs., Dusk-to-Dawn).
Bottom of Sensor
Avoid aiming the control at:
•  Objects  that  change  temperature  rapidly,  such  as 
heating  vents  and  air  conditioners.  These  heat 
sources could cause false triggering.
•  Areas where 
pets or traffic may trigger the control.
•  
Nearby large, light-colored objects reflecting light 
may trigger the shut-off feature. Do not point other 
lights at the sensor.
Clamp 
Screw
 
Ball 
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
  Least Sensitive 
 Most Sensitive
Sensor
WARNING: Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).
TEST AND ADJUSTMENT
 
Turn on the circuit breaker and light switch.
NOTE:  Sensor  has  a  1 
1
/
2
  minute  warm  up  period 
before it will detect motion. When first turned 
on, wait 1 
1
/
2
 minutes.
  Turn  the  RANGE  control  to  the  medium  position 
(halfway between MIN and MAX), Dual Light Level 
to  OFF,  and  the  ON-TIME  control  to  the  TEST 
position.
B
O
O
S
T
MAX
MIN
RANGE
ON - TIME DUAL BRITE
TEST  1   5   2 0
MINUTES
OFF  3  6   DUSK TO
HOUR   DAWN
DUAL LIGHT LEVEL