When “Error Code” appears
Check the error and perform Auto Calibration 
again.
1
When you press 
, “RETRY?” appears.
2
Press 
B/b to select “YES”.
3
Press .
The measurement starts in five seconds.
When “Warning” appears
If a warning on the measurement result is 
present, detailed information is displayed.
Press 
Tip
Depending on the position of the subwoofer, the 
measurement results for polarity may vary. 
However, there will be no problems even if you 
continue to use the receiver with that value.
Message list after Auto Calibration measurement
Display and explanation
Error Code 31
The SPEAKERS is set to off. Set it to others and perform the Auto Calibration again.
Error Code 32
None of the speakers were detected. Make sure that the optimizer microphone is connected properly and 
perform the measurement again.
If the optimizer microphone is connected properly but the error code appears, the optimizer microphone cable 
may be damaged or improperly connected.
Error Code 33
• None of the front speakers are connected or only one front speaker is connected.
• The optimizer microphone is not connected.
• Either the surround left or surround right speaker is not connected.
• Surround back speakers or front high speakers are connected even though surround speakers are not 
connected. Connect the surround speaker(s) to the SPEAKERS SURROUND terminals.
• The surround back speaker is connected only to the SPEAKERS SURROUND BACK/FRONT HIGH/
 
BI-AMP/FRONT B R terminals. When you connect only one surround back speaker, connect it to the 
SPEAKERS SURROUND BACK/FRONT HIGH/BI-AMP/FRONT B L terminals.
• Either the front left high or front right high speaker is not connected.
Warning 40
The measurement has completed. However, the noise level is high. You may be able to perform the 
measurement properly if you try it again, even though the measurement cannot be performed in all 
environments. Try to perform the measurement in a quiet environment.
Warning 41
The sound input from the optimizer microphone is outside the acceptable range. It is louder than the loudest 
sound that can be measured. Try to perform the measurement when the environment is quiet enough to allow 
proper measurement.
Warning 42
The volume of the receiver is out of the acceptable range. Try to perform the measurement when the 
environment is quiet enough to allow proper measurement.
Warning 43
The distance and position of a subwoofer cannot be detected. This may be caused by noise. Try to perform the 
measurement in a quiet environment.
NO WARNING