If SW1-1 is set to the on position, user mode is selected. In this case the user
has absolute control of the data and control signals for the ADC and DAC. With
SW1-1 in the on position, the logic that generates the control for SAM is
disabled and plays no active part in the process.
2.4
Connectors
In addition to jumpers and switches, the user also has access to various
connectors. This section details the pinout of each connector.
Reference
Designator
Description
J1
Analog input option for channel 0, miniature BNC
Cells in grey are not supported (tracked) directly by this EVM.
Reference
Designator
Description
Pin
Number
Function
J3
Analog input option
1
Noninverting input signal to dual operational amplifier, (2)
g
for universal
operational-amplifier
2
Noninverting input signal to dual operational amplifier, (2)
operational-amplifier
evaluation board, SIL
3
Inverting input signal to dual operational amplifier, (2)
evaluation board, SIL
PTH not installed.
4
Inverting input signal to dual operational amplifier, (2)
5
Nonfiltered output from dual operational amplifier, (2)
6
Filtered output from dual operational amplifier, (2)
7
+V supply
8
Operational amplifier (2) shutdown signal
9
Reference voltage
10
Analog ground
11
Operational amplifier (1) shutdown signal
12
–V supply
13
Nonfiltered output from dual operational amplifier, (1)
14
Filtered output from dual operational amplifier, (1)
15
Noninverting input signal to dual operational amplifier, (1)
16
Noninverting input signal to dual operational amplifier, (1)
17
Inverting input signal to dual operational amplifier, (1)
18
Inverting input signal to dual operational amplifier, (1)