Philips TDA1562Q 用户手册

下载
页码 24
2003 Feb 12
11
Philips Semiconductors
Preliminary specification
70 W high efficiency power amplifier
with diagnostic facility
TDA1562Q; TDA1562ST;
TDA1562SD
V
th2+
threshold voltage 2+
class-B
class-H
4.2
V
V
th2
threshold voltage 2
class-H
class-B
3.3
V
V
stH2
hysteresis
(V
th2+
V
th1
)
200
mV
P
IN
STAT
AS OUTPUT
I
st(mute)
mute acknowledge sink current
2.2
mA
V
st(mute)
mute acknowledge output voltage
I
st
= 2.2 mA
0.5
V
I
st(clB)
class-B operation output current
15
µ
A
V
st(clB)
class-B operation output voltage
I
st
= 15
µ
A
2.0
3.0
V
I
st(clH)
class-H operation source current
140
µ
A
V
st(clH)
class-H operation output voltage
I
st
=
140
µ
A
V
P
2.5
V
T
c(th)
threshold case temperature sensor
120
°
C
Diagnostic output DIAG
V
DIAG
output voltage
active LOW
0.6
V
R
L
load resistance for open load detection
100
Ω
T
j(th)
threshold junction temperature sensor
145
°
C
SYMBOL
PARAMETER
CONDITIONS
MIN.
TYP.
MAX.
UNIT
Fig.6  Supply voltage transfer characteristic.
handbook, full pagewidth
VPH1
Vth
Vth
+
MGL267
fast mute
on
VP