Rogue Audio M-120 用户手册

下载
页码 16
4)  Allign Tubes - Using a glove or a clean dry cloth, straighten any 
tubes that may have tilted during shipment as shown in figure 3. 
Ensure that tubes are fully seated in their ceramic sockets.  
 
MAINTENANCE 
 
 
The Rogue M-120 has been designed to provide many years of enjoyable 
and reliable service. The greatest care has been taken to select vacuum tubes 
that provide superior sound and ensure long life.  However, at some point in 
time, the tubes will wear out. The factory installed tubes should last 
thousands of hours.  Should it become necessary to replace a tube, follow 
the instructions listed below. 
Replace Tubes by : 
1)  Turn off power at switch. 
2)  Wait one hour for  dangerous voltages to dissipate. 
3)  Unplug power cord from wall socket. 
4)  Remove the tube cage.   
5)  Using a glove or clean dry cloth, carefully remove the tubes from 
their sockets - DO NOT TOUCH ANY OTHER ELECTRICAL 
COMPONENTS.  
6)  Obtain and insert a new set of tubes. It is recommended that a 
new set of tubes be obtained from Rogue. If tubes are obtained 
from another source, follow the diagram in figure 3 for tube type.  
7)  Insert new tubes in sockets using a glove or cloth. See figure 3 for 
locations.  
 
No other items in the unit are designed to be user serviceable
.  
 
WARNING - This amplifier uses voltages that could cause 
injury or death. Never open the amplifier while it is 
plugged in, and always wait at least one hour after turning 
the unit off  to unplug and open the unit.  Lethal
 voltages 
can remain in the electronics after the unit is unplugged.
 
Figure 3 
Rogue M-120 Owners Manual 
 
 
 
Rogue M-120 Owners Manual 
 
 
 
 
Power Tubes 
(KT88 or 6550) 
 
 
Power Tubes 
(KT88 or 6550) 
 
 
12AU7         12AX7          12AU7