Perreaux 750 用户手册

下载
页码 38
 
 
19 
  DC Offset Protection 
This  system  senses  if  any  direct  current  (DC)  is  present  at  the  750  output 
terminals  and  disconnects  the  output  to  avoid potential  speaker  damage.    DC 
may  be  present  due  to  ancillary  equipment  feeding  DC  into  the  input  or  an 
amplifier fault. 
Short-Circuit/Overdrive Protection 
This system senses if there is a short circuit across the 750 output terminals and 
disconnects the output to avoid amplifier damage.   It also senses  if the 750 is  
being  driven  outside  acceptable  operational  parameters.    An  example  of  this  
would be driving a 1Ω speaker at very high levels. 
Note:  After  the  short  circuit  or  overdrive  source  is  removed,  the  750  must  be 
turned off then back on to reset and resume operation. 
Thermal Protection 
This system senses if the 750 is overheating and disconnects the output until a 
safe operating temperature is reached, at which time the unit will automatically 
resume normal operation. 
Earthing  Perreaux  engineers  pay particular  attention to  designing  the  product  to  ensure 
maximum separation between internal signal and power earths, only meeting at a 
central starred point. 
Earth 
Isolation 
Switch 
The  toggle  switch  on  the  rear  of  the  750  allows  the  internal  circuitry  to  be 
isolated from the mains earth, whilst still maintaining an earth connection to the 
chassis.  This ensures the potentially fatal practice of using an AC cord-set with 
no earth connection, to alleviate system hum, is not required. 
Highest 
Quality PCBs 
and 
Components 
Quality  fibreglass  PCBs,  featuring  heavy  copper  tracks  and  high-grade 
components, are used throughout the 750.  This provides added stability under 
variable  thermal  or  electrical  loads  and  assures  maximum  signal  integrity, 
separation and product life. 
Bi-Wiring 
Made Easy 
Dual pairs of binding posts allow bi-wiring of speakers to be conducted easily. 
Soft-Start 
Circuitry 
The 750 utilises soft-start circuitry to protect the fuses and/or circuit breakers in 
your home’s mains power supply.  Without this circuit, the huge inrush current 
required  to  charge  the  60,000µF  of  power  supply  smoothing  capacitance  can 
blow the fuses or trip the circuit breakers. 
Highly 
Powered 
Capable of continuously delivering 750W
RMS
  into 8Ω (1300W
RMS
 into 4Ω), the 
750 is highly powered.  Utilising sixteen high current Toshiba M OSFETs, the 
750 handles even the most difficult loads with ease.