Pass Labs X250.5 用户手册

下载
页码 11
4
X250.5 Owners Manual
You  can  position  this  amplifier  most  anywhere  you  wish,  but  it  re-
quires  adequate  ventilation.    We  do  not  recommend  placing  it  in 
enclosed cabinets or small closets without means for air to circulate 
freely. Stacking these power amplifiers directly upon each other is not 
recommended  for  the  same  reason.  This  amplifier  typically  idles  at 
slightly less than 350 watts, most of  which dissipates as heat across 
the heatsinks. As a point of  reference, these heatsinks should never 
become too hot to touch for several seconds.
Let’s talk about AC power requirements.  This amplifier draws about 
3 amps (continuous rms) at 120 volts out of  the wall during normal 
operation, and this power draw reflects mostly the idle current that 
we run through the output stage.  If  you are driving a low impedance 
load, you will draw more power than this, but this will not be typical.
The  amplifier’s  voltage  and  current  rating  are  indicated  on  the  rear 
panel.  It will be 240 volts, 220 volts, 120 volts or 100 volts, all with 
an appropriate rear mounted resetable circuit breaker.  The frequency 
rating of  the AC line source in all instances will be 50 to 60 Hz.  Please 
verify that the amplifiers indicated voltage requirements are consistent 
with the line voltage supplied at your location.
The Pass Laboratories™ X250.5 is provided with a conventional IEC 
detachable AC line cord, which is rated at 15 amps. The safety ground 
is attached to the chassis in the conventional approved manner.  The 
AC power input to the amplifier runs through a RF filter, which re-
moves high frequency noise coming into and going out of  the ampli-
fier power supply.
Under no circumstances should you defeat the ground connection of  
the power cord.  For your safety, the chassis of  the amplifier should be 
earth grounded.  Signal ground is isolated from chassis, safety ground, 
to  reduce  the  incidence  of   ground  loop  noise.    The  presence  of   a 
safety ground will not degrade the audio signal chain.  
You may substitute an aftermarket detachable IEC 320 style power cord 
of  your choosing; provided it is rated for at least 15 amps and it meets all 
legal requirements and has been approved by the local testing authority 
for such things.
Looking  at  the  rear  panel  you  will  see  the  IEC  320  AC  power  cord 
receptacle, a thermal magnetic breaker switch, two pairs of  output con-
nectors, a pair of  binding post connectors for remote turn-on, one RCA 
input connector and one XLR balanced input connector.
Make sure that the breaker switch is off  (down).  Plug the AC cord into 
Setup