Mains Operation And Leakage Power
The mains power consumption as well as the leakage power is stated for driving the power amplifier at
different levels. All the values were measured at nominal load via the 100 V output with two channels
driven. The shown values differ only slightly when the appliance is operated at different nominal output
voltages or in the Direct Out mode.
mains operation at the 
100 V output
U
mains[V]
I
mains [A]
P
mains [VA]
P
mains [W]
P
out [W]
P
v [W]
BTU/hr
DPA 4245
idling
230V
0,34
78
47
47
160
normal operation (-10 dB)
230V
2,76
635
490
70
420
1430
alarm (-3 dB)
230V
5,54
1274
1040
352
688
2347
nominal conditions
230V
7,45
1714
1420
700
720
2456
DPA 4260
idling
230V
0,57
131
80
80
273
normal operation (-10 dB)
230V
3,66
842
655
101
554
1890
alarm (-3 dB)
230V
7,34
1688
1370
506
864
2948
nominal conditions
230V
9,86
2268
1900
1000
900
3070
initial current inrush for both models: < 38 A
P
mains
[VA] = apparent power U
mains
*I
mains
, P
mains
[W] = active power, P
out
[W] = output power, 
Pv[W] = leakage power, 1BTU = 1055.06 W/s
Fuses
location
pos.
utilization
value
dimensions
standard
rear panel DPA 4245
—-
mains fuse 230V~ AC
T8A 250V
5 x 20 mm
IEC 127
rear panel DPA 4260
—-
mains fuse 230V~ AC
T10A 250V
5 x 20 mm
IEC 127
print 84171/1
F1
power supply
T1A 250V
5 x 20 mm
IEC 127
print 84171/1
F2
power supply
T1A 250V
5 x 20 mm
IEC 127
Extension Kits For The DPA 4245 And The DPA 4260:
NRS 90208 balanced input (input transformer for a single channel)
NRS 90235 1 pair of rack-mount ears
26