Elmo DBP SERIES 用户手册

下载
页码 134
84
DBP - Rev 6/93
7.  Start - Up Procedures
7.1  Common procedures for all amplifiers types
7.1.1  Commutation signals format
Select the position of DIP switch 1 on the upper board of the power stage
according to the commutation signal format the motor has.
DS1 positions:
ON (down): 30
°
OFF (up): 60
°
For all Resolver versions it should be 60
°
.
7.1.2  CFM function
Select the position of DIP switch 2 on the upper board of the power stage
according to the motor's rated current. If it is less than 20% of the
amplifier's rated current select:
DS2 to ON (down)
Otherwise,
DS2 to OFF (up) - No CFM
7.1.3  Abort logic
Make sure that the Abort input is connected to a High (logic) voltage
source.