Creative 0404 用户手册

下载
页码 96
6 - Appendix
Word Clock In/Out
76
Creative Professional
Word Clock In/Out
f
Word clock and 
S/PDIF synchronize at the 
sample rate and are used 
to transfer digital data 
between machines.
Word clock provides a standardized means of synchronizing multiple digital audio 
devices so that data can be transferred digitally. In order to digitally transfer from one 
device to another, the two devices MUST be synchronized.
 Clicks and pops in the 
audio will result when transferring digital audio which is not synchronized.
The E-MU 0404 PCI card can be externally clocked from the S/PDIF input (either optical 
or electrical) or from the Sync Daughter card (if installed). In a digital studio, all 
digital devices in the system should run off the same master Word Clock
To Synchronize PatchMix DSP to an External Clock Source:
1.
Make sure an external clock source is connected to the E-MU Digital Audio System 
hardware via the word clock or S/PDIF input.
2.
Open the Session Settings dialog box.
3.
Under the System tab, select External Source, then select either Word Clock or 
S/PDIF.
4.
Press OK to close the dialog box.
5.
Check the Sync section of PatchMix DSP to verify that the Locked indicator is 
illuminated.
Devices can be connected in daisy chain fashion (word clock out connected to the next 
unit’s word clock in) or in parallel for one or two devices, but professional digital 
studios normally use a master word clock generator or “House Sync” with a distribution 
system so that each device receives a phase-coherent and jitter-free word clock.
Word Clock In: Receives word clock (sample clock) from another digital device such as 
a digital video deck, digital recorder or digital mixer.
Word Clock Out: Sends word clock (sample clock) to another digital recorder. Word 
clock is always output, whether it is generated by the internal clock or passed through 
from the word clock input.
75Ω On/Off: Termination for the word clock input can be switched on or off in the 
Sync Card menu of the PatchMix DSP application. Normally word clock termination 
should be left on. If you have problems with a weak word clock signal, try turning termi-
nation off. See 
.
The diagram below shows the proper way to connect and terminate a serial word clock 
chain. Using a BNC “T” connector ensures that word clock is precisely in phase for both 
devices. The middle device has termination turned Off and the last device in the word 
clock chain has termination turned On.
House Sync
Generator
Digital
Device 1
Digital
Device 2
Digital
Device 3
Digital
Device 4
A master word clock generator is preferable for larger digital setups.