4.3
Gateway Messages
4.3.1
Gateway Commands
The SAINT Gateway supports the following commands:
Header
ID
Data
Description
08h
80h
None
Perform Reset
08h
86h
None
Turn Time Stamp Information OFF
08h
87h
None
Turn Time Stamp Information ON
08h
88h
None
Turn Transmit Echo ON
08h
89h
None
Turn Transmit Echo OFF
08h
92
None
Request Software Version
08h
F0h
D1-D12
Enable Gateway Trigger
08h
F1h
None
Disable Gateway Trigger
4.3.1.1
Reset
This command will cause the gateway to do a complete cold start. The gateway will ignore the next message.
4.3.1.2
Time Stamp
This command controls whether a 16 bit time stamp is appended to the end of the bus message reports.
4.3.1.3
Transmit Echo
This command controls whether transmitted messages are echoed back to the host when they are sent. Echoed
back messages will have their transmit bit set. Currently the transmit echo is disabled.
back messages will have their transmit bit set. Currently the transmit echo is disabled.
4.3.1.4
Software Version Request
This command requests the gateway software version (ASCII).
4.3.1.5
Trigger
This command will cause the gateway to toggle the trigger LED upon receiving the specified byte pattern. Up to
12 data bytes may be used. This feature is helpful for triggering an oscilloscope. (Not available with IDB firmware)
12 data bytes may be used. This feature is helpful for triggering an oscilloscope. (Not available with IDB firmware)