Technical Specification 
 
 
Item  
Specification 
Maximum Switching Power 
24 W / 60 VA 
Minimum Switching Load 
0.1 mA, 100 mV DC 
B.6 
Environmental 
B.6.1 
Conditions 
Table B.29 Environmental Conditions 
Operational  
Specification 
Temperature 0
°C to +50°C ambient air temperature with free air-flow 
Humidity 
0% to 95% (non-condensing) 
Cooling requirements 
Convection cooling/free air-flow 
Handling/movement 
Fixed (non-mobile) use only 
Storage/Transportation 
Temperature -20
°C to +70°C (-4°F to +158°F) 
Humidity 
0% to 95% (non-condensing) 
B.7 
Compliance
B.8 
Safety 
This equipment has been designed and tested to meet the requirements of the 
following:  
EN 60950-1 
European 
Information technology equipment - Safety. 
  
IEC 60950-1 
 
International 
Information technology equipment - Safety.  
UL 60950-1 
 
USA 
Information Technology Equipment - Safety.  
                                                      
8
 The version of the standards shown is that applicable at the time of manufacture. 
 
EN/LZT 790 0003/2 R1A
 