Operating the Equipment Remotely 
 
 
Table 4.2  Configuring the Serial Remote Port and Activating Remote Protocol 
Step Action 
Result
 
1. 
Go to menu 7.1. 
Displays ‘OPERATING MODE’. 
2. Press 
Edit
Displays ‘FRONT PANEL’. 
3. 
Press the down pushbutton 
and select ‘SERIAL REMOTE’. 
The settings should be set to match the external 
control host. 
4. Press 
Save. 
The unit is ready for Remote Control. 
Once the communication parameters are entered correctly, set the system into 
remote mode for the external computer to gain control of the unit: 
 
Step Action 
Result
 
1. 
Go to menu 7.1.2. 
Displays ‘SERIAL REMOTE PROTOCOL’. 
2. Press 
Edit. 
Toggle between RS-232 Alteia or RS-485 Alteia. 
3. 
Chose between RS-232 Alteia 
or RS-485 Alteia. 
The settings should be set to match the external 
control host. 
4. Press 
Save. 
The unit is ready for Remote Control. 
4.1.5 
Configuring the Unit for Remote Control Over-air 
4.1.5.1 
Overview 
For the unit to be controlled via over-air control (OAC), the control mode of the Multi-
Format Receiver needs to be set to Director NCP. 
Table 4.3  Activating Director NCP Remote Control 
Step Action 
Result
 
1. 
Go to menu 7.1. 
Displays ‘OPERATING MODE’. 
2. Press 
Edit. 
Displays ‘FRONT PANEL’. 
3. 
Press the down pushbutton 
and select ‘DIRECTOR NCP’. 
The settings should be set to match the external 
control host. 
4. Press 
Save. 
The unit is ready for OAC. 
4.1.5.2 
OAC Lockout 
Once the unit is in OAC control mode, it is possible for the remote control operator 
to issue a local lockout command to the Receiver. This will effectively deny the local 
user access to configuring the unit. 
 