Ericsson RX1290 用户手册

下载
页码 176
Preventive Maintenance and Fault-finding 
 
 
 
EN/LZT 790 0003/2 R1A
 
7-8 
 
 
 
Caution! 
When replacing the power input fuse, always ensure that a fuse of the correct type 
and rating is fitted. Failure to do so results in inadequate protection. 
3.  Replace the fuse in the carrier. 
4.  Insert the fuse carrier back in the AC power inlet. 
 
To access the fuse, ease out the 
notch with a small flat-blade 
screwdriver. 
Fuse Carrier 
 AC Power Inlet 
Figure 7.2  Fuse Carrier 
If the replacement fuse also blows, do not continue. Disconnect the equipment and 
contact Customer Services (see Preliminary Pages) for advice. 
7.7 
Disposal 
7.7.1 
Molded Plugs 
If the molded plug fitted to the mains cable supplied with this equipment is not 
required, use another cable. If the supplied plug is to be changed, cut it off and 
dispose of it safely.  
Warning! 
 If the molded plug fitted to the mains cable supplied with this equipment is not 
required, please cut it off and dispose of it safely. Failure to do this may endanger 
life as live ends may be exposed if the removed plug is inserted into a mains outlet. 
7.7.2 
Equipment 
Dispose of this equipment safely at the end of its life. Local codes and/or 
environmental restrictions may affect its disposal. Check with your local authority.