INSTALLATION AND CONNECTIONS
• Using non-Icom exciters (transceivers) when the IC-PW1/EURO’s power is OFF
To use the antenna selector of the IC-PW1/EURO
while the power is OFF, follow 1 of 2 methods.
while the power is OFF, follow 1 of 2 methods.
(1) Supply the antenna selector power to the
ACC-1 socket
Supply the 13.8 V DC, 0.5 A to pin 7 of the [ACC-1]/
[ACC-2] socket.
[ACC-2] socket.
- Use [ACC-1] when the exciter is connected to [INPUT1].
- Use [ACC-2] when the exciter is connected to [INPUT2].
- Use [ACC-2] when the exciter is connected to [INPUT2].
(2) Use the auxiliary power supply
Set the jumper to ‘2’ to use the auxiliary power sup-
ply as shown at right.
ply as shown at right.
- The antenna selector functions even when the IC-
PW1/EURO power is OFF
In addition set the jumper on the IC-PW1/EURO con-
troller to ‘2’ to turn the controller’s LEDs OFF as
shown at right.
troller to ‘2’ to turn the controller’s LEDs OFF as
shown at right.
When the jumper is set to ‘2,’ the CI-V control does
not function even if an Icom exciter is connected.
not function even if an Icom exciter is connected.
These diagrams show the factory defaults.
J3
J4
S3
1 2
1
2
• Jumper location of linear amplifier
• Jumper location of controller
1
2
3
4
5
6
SEND ALC
RF
DC
GND
[ACC-1]
13.8 V DC
to IC-PW1/EURO [INPUT1]
to IC-PW1/EURO [GND]
IC-PW1/EURO (DIN)
Non-Icom exciter
NOTE: When using the antenna selector of the IC-PW1/EURO while the power is OFF, as above, tuner intial-
ization of the IC-PW1/EURO may not be performed correctly if the applied voltage is insufficient.
Check that the applied voltage to pin 7 of [ACC-1]/[ACC-2] socket is 13.8 V DC.
ization of the IC-PW1/EURO may not be performed correctly if the applied voltage is insufficient.
Check that the applied voltage to pin 7 of [ACC-1]/[ACC-2] socket is 13.8 V DC.