Kathrein VOS 30/F 用户手册

下载
页码 16
Type
 
VOS 30/F
VOS 40/F
Order no.
 20910002
20910012
Forward path
Frequency range
MHz
47 (85)-862
Gain (switchable)
dB
24/30
34/40
Amplitude ripple
dB
+/- 1.5
Adjustable attenuator setting range
dB
0-20
Equaliser setting range
dB
0-20
Interstage adjustable attenuator setting range
(can be switched with jumpers)
dB
0/6
Interstage equaliser setting range
(can be switched with jumpers)
dB
-
0/6
Maximum operating level
1)
 (60-dB CTB/CSO)
- fl at
- with 6-dB interstage pre-emphasis
dBµV
98/100
-
104/107
106/107
Noise fi gure
dB
7/6
Number of outputs
 
1
Return path
For data see VGR 28/xx
General
Impedance input/output
Ω
75
Return loss input/output
2)
dB
14
RF connections
F connector
Test socket output with directional coupler (5-862 MHz)
dB
-20
Test socket output return path (5-65 MHz)
dB
-20
Supply voltage
V
AC
198-253
Power consumption (without/with return path amplifi er)
W
7/9
6/7
Indication of operation mode
LED green
Protection class
II
Protection class (in accordance with EN 60529)
IP 50
Temperature range
°C
-20 to +55
Dimensions
mm
184 x 134 x 63
Packing unit/weight
pc./kg
1 (10)/1.6
1 (10)/1.4
1)
 In accordance with EN 60728-3; CENELEC channel plan 42 carriers
2)
 In accordance with EN 60728-3 (category C); from 40 MHz 14 dB-1.5 dB/octave, but 10 dB
936.2763/C/0703/1.4e/ZWT
•  House connection amplifi ers for modern HFC networks
•  Integrated power supply unit
•  Die-cast housing with F connectors
•  LED to indicate operation mode
•  Gain with interstage attenuation is switchable using jumpers 
(delivery condition: high gain)
•  VOS 40/F: Interstage equaliser (6 dB) can be connected using 
jumpers (Pre-emphasis)
•  Return path optional, can be confi gured as required:
  5-30 MHz with VGR 28/30
  5-65 MHz with VGR 28/65
  (delivery condition: without return path amplifi er, with jumpers)
•  Integrated, variable attenuator and variable equaliser
•  Test socket on output -20 dB (with directional coupler)
•  Test socket on input -20 dB (can be connected using jumpers) for return path levelling
•  Complies with: EN 60728-11, EN 50083-2 and EN 60065
•  For indoor installation
•  The amplifi ers comply with the requirements in the Low-Voltage Directive 2006/95/EEC and EMC Directive 2004/108/EEC 
applicable at the time of shipping.
House connection amplifi er
Return path amplifi er
VOS 30/F           20910002
VOS 40/F           20910012
VGR 28/30         20910008
VGR 28/65         20910009