24.3. Zone-to-Group Assignment Operation
• Here, the operation example of assigning Broadcast Zones 2 – 4 to Group 2 will be explained for a 5-zone
(Master unit only) configuration. (See p. 51 "Group 2 to zone" setting example.)
• In the case of 10 broadcast zones (i.e. connection of a master unit to a sub-unit), use the sub-unit's Zone
selector keys 1 – 5 as Zone keys 6 – 10.
Step 1. Entry to broadcast group setting mode
Press and release the Reset key while holding down the
ZONE 1 and ZONE 2 keys. When all indicators for
Zones 1 – 5 begin to flash (2 – 3 seconds after), release
both the ZONE 1 and ZONE 2 keys.
ZONE 1 and ZONE 2 keys. When all indicators for
Zones 1 – 5 begin to flash (2 – 3 seconds after), release
both the ZONE 1 and ZONE 2 keys.
Use a precision screwdriver or other long, pointed
object (2.5 mm in diameter and over 30 mm in length)
when pressing the Reset key.
object (2.5 mm in diameter and over 30 mm in length)
when pressing the Reset key.
Note: Even when a sub-amplifier is connected, perform
this setting entry operation on the master
amplifier only.
amplifier only.
The unit will be placed in broadcast group setting mode.
The 5 indicators for ZONE 1 through ZONE 5 begin to
flash. (They indicate Group 1 through Group 5.)
Another 5 indicators for ZONE 6 through ZONE 10 will
also flash if a Sub-amplifier is connected.
flash. (They indicate Group 1 through Group 5.)
Another 5 indicators for ZONE 6 through ZONE 10 will
also flash if a Sub-amplifier is connected.
Step 2. Group number selection (Example: Group 2)
Press the ZONE 2 key to select the Group 2.
The ZONE 2 indicator will slowly flash* to indicate that
Group 2 was selected.
Pressing other selector key will change the group
number
Group 2 was selected.
Pressing other selector key will change the group
number
Step 3. Group number programming
Press the POWER switch.
The Group 2 will be programmed and the unit will be
placed in Zone Selection mode for Group 2.
placed in Zone Selection mode for Group 2.
• The ZONE 2 indicator changes from "quick flashing" to
"slow flashing*," indicating that Group 2 was selected
and that Zone 2 was set (default setting).
and that Zone 2 was set (default setting).
• The remaining indicators, ZONE 1, ZONE 3, ZONE 4,
ZONE 5, and ALL flash. (This indicates that Zones 2
was set as default.)
was set as default.)
ZONE 1
ZONE 2
Reset
Extinguished
Lighting
Flashing
Quick flashing*
Slow flashing*
* See p. 55 Indicator status.
Lighting status
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ALL
Group 1
Group 5
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ALL
Group 1
Group 5
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ALL
Zone 1
Group 2
(Zone 2)
(Zone 2)
Zone 5