National Instruments 320571-01 用户手册

下载
页码 157
Chapter 2 NI-DSP Analysis VI Reference
NI-DSP SRM for LabVIEW for Windows 2-8 Part 3:  NI-DSP Function Reference
DSP Blackman Harris Window
Applies a Blackman Harris window to
the input sequence X.  If Y represents
the output sequence Blackman
Harris{X}
, the elements of Y are
obtained using the following formula:
y
i
  =  x
i
 [0.42323 - 0.49755 cos(w)
+0.07922 cos(2w)]
for  i = 0, 1, 2, … , n-1
w  =  
2
π
i
n
   ,
where n is the number of elements in X.
X is a DSP Handle Cluster that indicates the memory buffer on the DSP board that contains the input
signal array.
Note: The operation is performed in place and the input array is overwritten by the output
Blackman Harris {X}.
Blackman Harris {X} is a DSP Handle Cluster that is identical to X, but with the results of Blackman
Harris {X}
 already stored in the memory buffer on the DSP board.
error in (no error) contains the error information from a previous VI.  If an error occurs, it is passed out
error out and no other calls are made.
error out contains the error information for this call.