44    Operational Reference 
Genie Monochrome Series-GigE Vision Camera 
External Trigger Programmable Exposure 
•  Also known as “Edge Pre-select” exposure. See the timing diagram below.  
•  The external trigger edge initiates the exposure process. The active external trigger edge can be selected as 
either the low-high or high-low transition.  
•  The delay from active trigger edge to start of exposure is programmable from 1μs to 4 seconds (1μs steps) .  
•  Exposure duration is programmable from 100μs to 4 seconds (1μs steps).  
•  Supports 
" on page 46
 timing for fastest possible frame rates. Start of exposure is aligned 
on the next horizontal line while exposure duration granularity is 1µs. Exposure and sensor readout can be 
concurrent. 
•  Supports 
 timing. Exposure granularity is 1µs. Exposure and sensor readout must be 
sequential, limiting the maximal frame rate. 
•  Any external trigger received before the previous exposure is complete is ignored. An application can elect to 
receive messages about ignored triggers. See 
" on page 63
 
 