Faber M640 用户手册

下载
页码 127
82    Network Tools 
Genie Monochrome Series-GigE Vision Camera 
 
After installation, all system NIC devices have the Sapera Network Imaging driver enabled. Only the NIC 
connected to a Genie camera requires the Network Imaging driver enabled to capture images from Genie. The 
Network Imaging driver streams image data efficiently to image buffers.  
Select other NIC devices in the system and disable the Network Imaging Driver if they are not used with a Genie 
camera.  
Recovering a Camera with an Unknown Persistent IP 
When a Genie camera has been configured with a persistent IP address, that camera can not be controlled if its IP 
address has been lost or forgotten. The DALSA Network Configuration tool provides a function to recover cameras 
and reset them back to the DHCP/LLA mode. The camera can also be set to a new persistent IP address immediately 
if required.  
 
 
Important: To recover a Genie camera, the camera MAC address must be known. DALSA ships all Genie 
cameras with a label stating its serial number and MAC address. Additionally the NIC connected to the Genie 
must be configured for LLA mode.  
 
To recover a Genie: 
•  Start the Network Configuration program from the windows start menu: Start•Programs•DALSA•Network 
Interface•DALSA Network Configuration Tool.  
•  From the menu bar click on Advanced and then on Recover Camera.  
•  On the dialog enter the camera MAC address and click the Recover Camera button.  
 
Camera Recovery Dialog