Sanyo VCC-MD800 用户手册

下载
页码 42
− 31 −
[8]  Aperture
Emphasizes contours and increases the vividness of 
the entire image.
[9]  Motion Detection
The screen is divided into 48 areas (8 x 6) and 
movement is detected from changes in brightness of 
representative points within each area.
The detection status can be confirmed by enquiring 
using the Status command.
In addition, the detection sensitivity can be adjusted 
by configuring the following items.  
Sensitivity (MOVE)
 
Sensitivity when determining movement can be 
configured to a range of 1 to 10. 1 is the most 
sensitive to movement.   
Brightness Level (Y-LEVEL)
 
Settings for minimum brightness level when 
determining movement (Valid for brightness above 
the configured level)
The configuration range is 1 to 10. 1 is the most 
sensitive to the minimum brightness level.  
Brightness Difference (Y-Differ)
 
Settings for differences in brightness of the 2 
images when determining movement (Invalid when 
exceeding configured brightness differences)  
The configuration range is 1 to 10. 1 is the most 
sensitive to the difference in maximum brightness.
Time Interval (Duration)
 
Time interval settings when determining movement
The configuration range is 1 to 60. 1 is the most 
sensitive to minimum time intervals.
Time intervals are divided into 5 fields.
 
Movement Assessment Confirmation Mode (TEST)
[10] Day/Night Switch Control
AUTO
 
Automatically switches the camera from color 
images to black and white images depending on 
the brightness of the day and night. The illumination 
level at which the camera changes from color 
images to black and white images can be set to 
3 levels (MID, HIGH, LOW) or to manual (ADJ) 
setting. 
COLOR
 
Fixes the camera to color images.
B/W
 
Fixes the camera to black and white images.
Function Descriptions