6.4.6. PIV mode. 
PIV mode (Particle Image Velocimetry) can be used in applications where 2 images should be 
taken with a very short time interval. It can only be used with strobe flash as illumination. The 
first accumulation time is fixed at 4 µsec. After a delay >1.5 µsec. the second exposure period 
starts. It is as long as the time for a full frame. The accumulation is LVAL a-synchronous. The 
first exposure period starts at the trigger leading edge. The first strobe flash should be fired 
within the first exposure period, and the second strobe flash during the first frame read out 
period. The result will then be 2 frames exposed with the flash interval.   
 
To use this mode:  
Set function: 
Trigger mode “PIV”  
TR=5 
 
LVAL synchronous accumulation 
LS=1  
 
Scanning format 
SC=0 through SC=4 
 
Output select 
OS=0, OS=1 
 
Polarity and other functions 
Input: 
Ext. trigger to Camera Link or pin 10 on 12-pin connector.  
 
2 strobe flash  
 
 
 
Important notes on using this mode.
 
•  The duration of the trigger should be >2LVAL to <3FVAL.  
•  A new trigger must not be applied before FVAL is low after second frame readout. 
•  1LVAL = 47.9 µsec (single). 27.3 µsec (dual). 
 
For horizontal timing refer to 6.2.3. through 6.2.6. (Fig.17. through fig. 20.) 
For LVAL a-synchronous accumulation refer to 6.2.8. (fig. 22.) 
LVAL
DATA  OUT
SUB
SG
FVAL
EEN
Ext . Tr i g1
Second  Fr ame
4us( 1/ 250, 000s)
Fi r st   Exposur e  Per i od
1  f r ame  r ead- out   per i od
Second  Exposur e  Per i od
Fi r st   Fr ame
Readout   del ay:
1  t o  2L
Mi n. : 2L
 
 
Fig. 28. PIV mode  
LVAL
FVAL
SUB
SG
104ck
Exposur e
Per i od
52ck
40ck( 1us)
120ck( 3us)
Ext . Tr i g
Exposur e  del ay:
156ck( 3. 9us)
Fi r st   exposur e  t i me:
160ck( 4us)
EEN
60ck( 1. 5us)
  
Fig. 28A. PIV mode details