Intel NSC2U 用户手册

下载
页码 20
TMLPMOUNT41, TMLPMOUNT51 and TMLPMOUNT52 
 
TMLPMOUNT41/51/52 series mounts Intel® Communication Rack Mount Servers to 2-
post or 4-post racks. 
 
TMLPMOUNT41 and TMLPMOUNT51 are used for mounting servers on 19-inch wide racks. 
These racks are considered standard EIA (universal hole spacing) racks. 
 
TMLPMOUNT52 is used for mounting servers on 23-inch wide racks. These racks could be 
standard EIA (universal or wide hole spacing) or ETSI (European) racks. 
 
TMLPMOUNT41/51/52 series are designed with a slide-in rail-type system. Although the 
mounts are designed as rails, they are not sliding rails. This means the servers can be slid 
into the racks for installation purpose, but the rails are not designed to support a mounted 
server during service. 
 
TMLPMOUNT4x/5x Feature Comparison 
 
Slide pull-out 
locking feat
ure 
Slide interface 
material 
4-post rack hole 
spacing 
2U-tall nut 
bar 
2-post chassis 
securing screw 
location 
"HP Mulan 
rack 
interferenc
e
TMLPMOUNT41 No
1
 
Plastic 
strips
2
 
EIA-Universal 
Not 
included 
Side 
access
6
 
Interference 
TMLPMOUNT51 Yes 
Xylan 
coating
3
 
EIA-Wide or EIA-
Universal
4
 
Included
5
 
Front 
access 
No Interference 
TMLPMOUNT52 Yes 
Xylan 
coating
3
 
EIA-Wide, EIA-
Universal or ETSI 
Included
5
 
Front 
access 
N/A 
 
Notes: 
1.  Extra care must be exercised with TMLPMOUNT41 to securely hold the server with one's hands 
when sliding it out of the rack; otherwise, the server could fall to the ground as it is being 
removed. 
2.  Plastic strips on TMLPMOUNT41 have peeled off in some customer installations.  The result of 
this is that the parts are usable, but the server could have somewhat of a "scrape-in feel" rather 
than "slide in". Also, the rails will fit sloppier, so the side-located chassis securing screws could 
be difficult to align in 2-post installations. Replacement material is available from the plastic 
strip manufacturer. 
3.  Xylan is a tough, low-friction coating similar to Teflon. 
4.  EIA-Wide spacing doesn't have the interstitial hole that is present in EIA-Universal. 
TMLPMOUNT51 contains an adapter bracket to overcome this EIA-Wide issue. 
5.  This component (2U Nut Bar) enables installation of a rail kit into a 1U rack slot when there is 
already equipment installed both above and below that open slot. 
6.  The sides of the server must be accessible when using TMLPMOUNT41 in 2-post racks. 
 
 
 3/28/2008 