DS1 Circuit Pack 
17
Slip Detection
Slips — synchronization errors — slow digital transmissions and can result in 
data loss. The switch maintains a slip-count record for each DS1 interface to 
detect errors and evaluate their severity (the type of alarm). If as many as 50 
percent of those spans administered for slip detection are experiencing slips (with 
respect to the primary), then a decision is made to switch to the secondary.
!
CAUTION:
Always enter 
y
 for DS1 circuit packs that serve as primary or secondary 
synchronization references. 
Near-end CSU Type
This field appears only when the DS1 circuit pack is a TN767D or TN464E or 
later suffix model, the Bit Rate field is 
1.544
 and the Country Protocol field is 
1
 
(U.S.). This field does not display for all circuit packs.
Valid entries
Usage
y
Enter 
y
 to allow maintenance software to measure the slip-rate 
of this circuit pack and determine whether it’s excessive. 
Typically, enter 
y
 for DS1 spans used for data applications and 
for spans used as synchronization references. This excludes all 
T1-spans connecting channel banks, unless the channel bank is 
externally timed. This entry enables switching between the 
primary and secondary synchronization references and an 
internal high-accuracy clock.
n
 Enter 
n
 for DMI-BOS links or when testing is not required. 
Normally, enter 
for
 
DS1 spans that are used exclusively for 
voice and that do not serve as the primary or secondary 
synchronization source.
Valid entries
Usage
other
Enter 
other
 if no channel service unit is attached to the DS1 
facility or if the CSU is an external unit. No options are 
available on page 2 for administering an external CSU.
integrated
Enter 
integrated 
if a 120A CSU module is attached to the DS1 
board. This integrated channel service unit (ICSU) can accept 
software-administrable option downlinks (that is, it can respond 
to test codes from technician’s equipment and report its status). 
When you enter 
integrated
, fields for administering options on 
the ICSU appear on page 2 of the DS1 Circuit Pack screen.