Lucent Technologies 8.2 用户手册
DEFINITY ECS Release 8.2
Administrator’s Guide
Administrator’s Guide
555-233-506
Issue 1
April 2000
Screen reference
681
Group Paging Using Speakerphone
17
Automatic Exclusion with Whisper Page
Appears when Automatic Exclusion by COS field is
y
.
Recall Rotary Digit
This establishes the digit to use for rotary phones to receive recall dial tone.
Dialing this digit simulates switch hook flash so that users of rotary phones can
use features such as conference and transfer. The phone must also be administered
to use the recall rotary digit.
Dialing this digit simulates switch hook flash so that users of rotary phones can
use features such as conference and transfer. The phone must also be administered
to use the recall rotary digit.
Password to Change COR by FAC
Appears if, on the System-Parameters Customer-Options screen, the Change COR
by FAC field is
by FAC field is
y
. Lucent recommends using this password option.
Group Paging Using Speakerphone
Use this screen to assign digital speakerphones to a paging group. Users can page
all the phones in the group simultaneously by dialing the group’s extension.
all the phones in the group simultaneously by dialing the group’s extension.
Valid entries
Usage
y
The whisper page goes through to an excluded call.
n
The whisper page is denied when a station attempts to whisper
page to a station that is on an excluded call.
page to a station that is on an excluded call.
Valid entries
Usage
0–9
Enter the digit users can dial to generate recall dial tone. Use a
number that is not the first digit in normal dialing patterns.
number that is not the first digit in normal dialing patterns.
Valid entries
Usage
4 - 8 digits
Requires the password option.
blank
Disables the password option.